Refrigerant Cycle Diagram - Ras-B13N3Kv2-E / Ras-13N3Av2-E - Toshiba RAS-B10N3KV2-E Service Manual

Split type air conditioner
Hide thumbs Also See for RAS-B10N3KV2-E:
Table of Contents

Advertisement

RAS-B13N3KV2-E / RAS-13N3AV2-E
P
Pressure measurement
Gauge attaching port
Vacuum pump connecting port
Deoxidized copper pipe
Outer dia. : 9.52mm
Thickness : 0.8mm
4-way valve
TS
Temp. measurement
NOTE :
• The maximum pipe length of this air conditioner is 20 m. When the pipe length exceeds 15m, the additional
charging of refrigerant, 20g per 1m for the part of pipe exceeded 15m is required. (Max. 100g)
INDOOR UNIT
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Muffler
Muffler
TD
Compressor
DA89X1C-23FZ2
Outdoor heat
exchanger
T2
Propeller fan
OUTDOOR UNIT
Temp. measurement
T1
TC
TA
TO
TE
NOTE :
20
FILE NO. SVM-12050
Max.
Min.
Chargeless : 15m
Charge : 20g/m
(16 to 20m)
Strainer
Pulse Modulating
valve at liquid side
Refrigerant amount : 0.80kg
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
: 20m
: 2m