Remote-A Or B Selection - Toshiba RAS-B10N3KV2-E Service Manual

Split type air conditioner
Hide thumbs Also See for RAS-B10N3KV2-E:
Table of Contents

Advertisement

Item
• Self-Cleaning diagram
13. Self-Cleaning
function
Operation display
FCU fan
FCU louver
Timer display
depend on presetting of timer function.
Compressor
depend on presetting per room temperature.
CDU fan
depend on presetting per room temperature.
operation more than 10 mins.
14. Remote-A or B
Setting the remote controller
selection
To separate using of remote control for each indoor
unit in case of 2 air conditioner are installed nearly.
Remote Control B Setup.
1) Press RESET button on the indoor unit to turn
2) Point the remote control at the indoor unit.
3) Push and hold CHK • button on the Remote
4) Press MODE • during pushing CHK • . "B" will
Note : 1. Repeat above step to reset Remote Control
Operation flow and applicable data, etc.
ON
ON
rpm is depend on presetting.
OPEN
ON or OFF
ON or OFF
ON or OFF
Cool mode or dry mode
Turn off by remote controller or
timer-off function.
the air conditioner ON.
Control by the tip of the pencil. "00" will be shown
shown on the display.
show on the display and "00" will disappear and
the air conditioner will turn OFF. The Remote
Control B is memorized.
to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
factory is A.
OFF
ON
(500RPM)
OPEN (12.7º)
ON
OFF
OFF
Self-Cleaning mode
operate 30 mins.
Automatically turn-off.
1. Purpose
This operation is to operate only one
indoor unit using one remote controller.
2. Description
When operating one indoor unit in a
situation where two indoor units have
been installed in the same room or
nearby rooms, this operation prevents the
remote controller signal from being
received simultaneously by both units,
thus preventing both units from operating.
3. Operation
The indoor unit on which the remote
controller selection has been set to B
receives the signal of the remote control-
ler also set to B.
(At the factory the remote controller
selection is set to A on all the indoor
units. There is no A setting display.)
− 39 −
FILE NO. SVM-12050
Description
OFF
OFF
CLOSE
ON or OFF
depend on presetting of timer function.
OFF
OFF
Operation time

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10n3av2-eRas-b13n3kv2-eRas-13n3av2-e

Table of Contents