Setting List For Redundant Safety Controller (Watlow) - AEC AD Series Operation And Installation Manual

Ad series dehumidifying dryers
Table of Contents

Advertisement

Setting List for Redundant Safety Controller (WATLOW), Part No. A0555757
Mode
Parameter
SEn
Sensor Type
Thermocouple
Lin
Linearization
C-F
Temperature Units
S.dEC
Temp. Decimal Places
IS.En
INFOSENSE™
Sc.Lo
Process Scale Low
Sc.hi
Process Scale High
CAL
Calibration Offset
Ftr.E
Input Filter
Ot 1
Output 1 Function
LSd1
Output 1 Limit Sides
hyS1
Limit 1 Hysteresis
Ot2
Output 2 Function
LSd2
Output 2 Sides
UdSP
Upper Display Look
LdSP
Lower Display Look
LOC
Lockout
Page 42
Figure 11
Setting range
0-3
0-10
Fahrenheit / Celsius
0 – 0.0
Yes / No
4.00 to 20.00 mA
1.00 to 10.00V
4.00 to 20.00 mA
1.00 to 10.00V
-999 to 999
Off, DiSP, Cont, both
Limit (2)
Both, High, Low
0.0 to 999.0
Off / Process Alarm / Limit (2)
Both / high / low
None, Process Value, Limit 1 Low
Set, Limit 1 High Set, Limit 2 Low
Set, Limit 2 High Set, Alarm 2 Low
Set, Alarm 2 High Set, Limit 3 Low
Set, Limit 3 High Set, Alarm 3 Low
Set, Alarm 3 High Set
None, Process Value, Limit 1 Low
Set, Limit 1 High Set, Limit 2 Low
Set, Limit 2 High Set, Alarm 2 Low
Set, Alarm 2 High Set, Limit 3 Low
Set, Limit 3 High Set, Alarm 3 Low
Set, Alarm 3 High Set
(0) no lockout, (1) Programming
and Setup Page Locked, (2) Limit
Set Points are the only Operation
Page parameters accesible, (3) Full
Lockout.
Default
AEC setting
0
0
F
0
No
4.00 mA
1.00V
20.00 mA
5.00 V
0
OFF
(2)
Both
1.0
OFF
Both
Process
Limit 1
High Set
0
AD Series Dehumidifying Dryers
-
H (1)
-
-
-
0
400
-
-
-
High
-
-
-
-
-
2