Desiccant Bed Location & Disassembly - AEC AD Series Operation And Installation Manual

Ad series dehumidifying dryers
Table of Contents

Advertisement

Desiccant Cap
13X Molecular Sieve
8x12 Beads
Regeneration Heater
Regeneration
Thermocouple
(2) 4-40 screws
Hi Temperature
Snap Switch
Important!
AD Series Dehumidifying Dryers
To access the Desiccant Bed:
Disconnect electrical power to the dryer.
Using a 1/8" Allen wrench, remove the four (4) 10-32
button head screws holding the Dessicant Cap to the
Regeneration Heater.
Remove the Desiccant Cap.
With a shop vacuum, carefully remove all desiccant from
each tower.
Figure 13
Desiccant Bed Location and Disassembly
Undo (4) 10-32 Button
Head Screws using 1/8
Allen Wrench
You should properly dispose of any discarded desiccant.
Consult local disposal regulations for more information.
Inspect each lower desiccant screen for tears or holes where
desiccant burned-through. Replace as needed.
1" Wide x 1/8" Thick Silicon
Strip and Stick Gasket
16 Mesh 0.028 Diameter Wire
Stainless Steel Screen
1" Wide x 1/8" Thick High
Temperature Gasket
Page 57