Replacing/Cleaning The Regeneration Heater/Cooling Coils; Heating/Cooling Coil Location & Disassembly - AEC AD Series Operation And Installation Manual

Ad series dehumidifying dryers
Table of Contents

Advertisement

8-7
Replacing/Cleaning the Regeneration
Heater/Cooling Coils
WARNING!
HAZARDOUS ELECTRICAL CURRENT PRESENT.
Disconnect and lock out power before you replace
heater elements!
1" Wide x 1/8" Thick High
Temperature Gasket
Undo (4) 10-32 Button
Head Screws using 1/8
Allen Wrench
Page 60
Figure 16
Heating/Cooling Coil Location and Disassembly
In order to gain access to the regeneration heater, the cover plate
on the side of the dryer must be removed. This cover plate is
secured by four (4) 10-32 bolts.
Sketch the heater wiring configuration so you can properly re-
assemble the heaters.
Disconnect the wiring for the heater being removed or replaced.
Remove the Cooler/Filter housing by undoing the bolts holding it
in place. Once the fastners are undone, take out the housing.
Use compressed air or a steam
cleaner to blow the dust off or clean
any oily residue on the coil.