Setting List for Redundant Safety Controller (WATLOW), Part No. A0555757
Mode
Parameter
SEn
Sensor Type
Thermocouple
Lin
Linearization
C-F
Temperature Units
S.dEC
Temp. Decimal Places
IS.En
INFOSENSE™
Sc.Lo
Process Scale Low
Sc.hi
Process Scale High
CAL
Calibration Offset
Ftr.E
Input Filter
Ot 1
Output 1 Function
LSd1
Output 1 Limit Sides
hyS1
Limit 1 Hysteresis
Ot2
Output 2 Function
LSd2
Output 2 Sides
UdSP
Upper Display Look
LdSP
Lower Display Look
LOC
Lockout
Page 42
Figure 11
Setting range
0-3
0-10
Fahrenheit / Celsius
0 – 0.0
Yes / No
4.00 to 20.00 mA
1.00 to 10.00V
4.00 to 20.00 mA
1.00 to 10.00V
-999 to 999
Off, DiSP, Cont, both
Limit (2)
Both, High, Low
0.0 to 999.0
Off / Process Alarm / Limit (2)
Both / high / low
None, Process Value, Limit 1 Low
Set, Limit 1 High Set, Limit 2 Low
Set, Limit 2 High Set, Alarm 2 Low
Set, Alarm 2 High Set, Limit 3 Low
Set, Limit 3 High Set, Alarm 3 Low
Set, Alarm 3 High Set
None, Process Value, Limit 1 Low
Set, Limit 1 High Set, Limit 2 Low
Set, Limit 2 High Set, Alarm 2 Low
Set, Alarm 2 High Set, Limit 3 Low
Set, Limit 3 High Set, Alarm 3 Low
Set, Alarm 3 High Set
(0) no lockout, (1) Programming
and Setup Page Locked, (2) Limit
Set Points are the only Operation
Page parameters accesible, (3) Full
Lockout.
Default
AEC setting
0
0
F
0
No
4.00 mA
1.00V
20.00 mA
5.00 V
0
OFF
(2)
Both
1.0
OFF
Both
Process
Limit 1
High Set
0
ACM Series Dehumidifying Dryers
-
H (1)
-
-
-
0
400
-
-
-
High
-
-
-
-
-
2