1. Model MN060HBA shall not be installed
in a bedroom. Models MN100HBA and
MN100TBA shall not be installed in a
bedroom or bathroom.
2. This heater needs fresh air ventilation to
run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater
if not enough fresh air is available. See Air
Combustion and Ventilation
for
7 through 9. If heater keeps shutting off,
Troubleshooting
see
3. Keep all air openings in front and bottom
of heater clear and free of debris. This will
ensure enough air for proper combustion.
4. If heater shuts off, do not relight until you
have provided fresh, outside air. If heater
keeps shutting off, have it serviced.
MODEL
Ignition
Gas Type
BTU (available)
Pressure Regulator Setting
Inlet Gas Pressure*
(inches of water)
Heater Dim. (HxWxD)
Carton Dim. (HxWxD)
Heater Weight
Shipping Weight
Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).
* For purposes of input adjustment.
4
SAFETY
, pages
, page 21.

SPECIFICATIONS

MN060HBA
Piezo
Natural Gas
6,000
3" W.C.
Maximum 10.5"
Minimum 4"
19
/
" × 14
/
" × 6
1
1
3
8
8
22" × 16
/
" × 8
/
3
1
4
8
13 lbs
16 lbs
www.usaprocom.com
5. Do not run heater:
• Where flammable liquids or vapors are
used or stored.
• Under dusty conditions.
6. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater off.
If heated, the vapors from these products
may create a white powder residue within
burner box or on adjacent walls or furniture.
7. Do not use heater if any part has been
under water. Immediately call a qualified
service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
8. Turn off heater and let cool before servic-
ing. Only a qualified service person should
service and repair heater.
9. Operating heater above elevations of
4,500 feet could cause pilot outage.
MN100HBA
Piezo
Natural Gas
6,000/10,000
3" W.C.
Maximum 10.5"
Minimum 4"
/
" 19
/
" × 14
/
" × 6
1
1
8
8
8
"
22" × 16
/
" × 8
3
4
13 lbs
16 lbs
MN100TBA
Piezo
Natural Gas
10,000
3" W.C.
Maximum 10.5"
Minimum 4"
/
" 19
/
" × 14
/
" × 6
3
1
1
8
8
8
/
"
22" × 16
/
" × 8
1
3
8
4
14 lbs
17 lbs
200044-01A
/
"
3
8
/
"
1
8

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MN060HBA and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Mn100tbaMn100hba

Table of Contents