Specifications - Procom BLUE FLAMEMNSD200TBA Owner's Operation And Installation Manual

Vent-free gas wall heater
Table of Contents

Advertisement

1. Do not place Propane/LP supply tank(s)
inside any structure. Propane/LP supply
tank(s) must be placed outdoors.
2. Heaters with a maximum input over
6,000 Btu/Hr shall not be installed in a
bathroom. Heaters with a maximum input
over 10,000 Btu/Hr shall not be installed
in a bedroom.
3. This heater needs fresh air ventilation to
run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater
if not enough fresh air is available. See
Air for Combustion and Ventilation, pages
7 and 8. If heater keeps shutting off, see
Troubleshooting, page 25.
4. Keep all air openings in front and bottom
of heater clear and free of debris. This will
ensure enough air for proper combustion.
5. If heater shuts off, do not relight until you
have provided fresh, outside air. If heater
keeps shutting off, have it serviced.
6. Do not run heater:
• Where flammable liquids or vapors are
used or stored.
• Under dusty conditions.
MODEL
BTU (available)
Ignition
Gas Type
Pressure Regulator Setting
Inlet Gas Pressure*
(inches of water)
Gas Type
Pressure Regulator Setting
Inlet Gas Pressure*
(inches of water)
Heater Dimensions (HxWxD) 19
Carton Dimensions (HxWxD)
Heater Weight
Shipping Weight
4
SAFETY
7. Before using furniture polish, wax, carpet
8. Manual Control Models Only: Always
9. Do not use heater if any part has been
10. Turn off and unplug heater and let cool
11. Operating heater above elevations of
12. To prevent performance problems, do

SPECIFICATIONS

MNSD100TBA
10,000
Electric Piezo
Using Natural Gas
4" W.C.
Maximum 9"
Minimum 5"
Using Propane Gas Using Propane Gas Using Propane Gas
9.5" W.C.
Maximum 14"
Minimum 11"
/
" × 14
/
" × 6
/
" 23
1
1
3
8
8
8
22 ×16
/
" × 8
/
"
3
1
4
8
14.6 lbs
17.6 lbs
www.usaprocom.com
cleaner, or similar products, turn heater off.
If heated, the vapors from these products
may create a white powder residue within
burner box or on adjacent walls or furniture.
run heater with control knob at PILOT/
IGN, LOW (1) or HIGH (5) locked positions.
Never set control knob between locked
positions. Poor combustion and higher
levels of carbon monoxide may result.
under water. Immediately call a qualified
service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
before servicing. Only a qualified service
person should service and repair heater.
4,500 feet could cause pilot outage.
not use propane/LP fuel tank of less than
100 lbs. capacity.
MNSD200TBA
20,000
Electric Piezo
Using Natural Gas
4" W.C.
Maximum 9"
Minimum 5"
9.5" W.C.
Maximum 14"
Minimum 11"
/
" × 19
/
" × 8" 23
1
1
2
4
25
/
" × 21
/
" × 9
/
" 25
3
3
1
4
4
4
22.2 lbs
26.2 lbs
MNSD300TBA
30,000
Electric Piezo
Using Natural Gas
4" W.C.
Maximum 9"
Minimum 5"
9.5" W.C.
Maximum 14"
Minimum 11"
/
" x 26
/
" x 8"
1
5
2
8
/
" x 28
/
" x 9
/
"
3
1
1
4
2
4
28.1 lbs
33.1 lbs
200213-01B