Page 1
24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: 44/(0) 1489-566300 Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed to be used in life-critical situations and must not be used for this purpose.
(10BaseT/100BaseTX Ethernet). This socket could also be used to power the V992D-IR via Power over Ethernet (PoE). The V992D-IR auto-senses the correct power level when using a PoE (Class 2) switch, router or injector.
2. Installation 2.1 Remove Dome Cover Turn counterclockwise the dome cover by grasping the bottom of the camera. Adjust Image Position The orientation of the camera up and down on the position of the image you want, please adjust left and right. Ports and Buttons...
Page 5
Mounting to a ceiling / wall IN CEILING MOUNT...
2.1 Assign IP address The default setting of the V992D-IR is set “DHCP” to ON. If you have a DHCP server on your network and UPnP function enabled on your PC you can find the network V992D-IR in “My network”.
4. The default user name is ADMIN, and password is 1234. 5. The V992D-IR’s Live View page is now displayed in your browser. When you first access the V992D-IR you will be asked to download and install an Active X control from the V992D-IR to display a Live image.
NOTE: The layout of the live view page in the V992D-IR may have been customized to meet specific requirements. Consequently, some of the examples and functions featured here may differ from those displayed on your own Live View page. 2.4 Accessing the V992D-IR from the Internet Once installed, the V992D-IR is accessible on the local network (LAN).
3. Live View Digital Zoom Snap Shot Full Screen Video Stream change: First stream Second stream Play: Click this button by manually to start the stream Stop: Click this button by manually to stop streaming NOTE: It is possible that not all the buttons described below will be visible unless the Live View page has been customized to display them.
(intranets), as each user needs an uninterrupted data flow and should not rely on network routers. (Note that multicasting may not be available with the firmware you received; check the Vicon website for updated firmware.) 3.2 How to Stream H.264...
• Administrators, who have unrestricted access to all settings under the Setup tab. Accessing the Setup link from a browser 1. Start your web browser and enter the IP address or host name of the V992D-IR into the address bar.
4.2 Video The following descriptions show examples of some of the features available with V992D-N4. 4.2.1 Codec This section allows you to choose the compression codec for each of the video streams. Codec H.264 This is a video compression standard that makes good use of bandwidth and could provide high-quality video streams.
Page 14
V992D-IR in the field above. When motion is detected, the V992D-IR will boost the fps from the regular level set for the V992D-IR to this boosted level for the duration of the motion. Boost Quality can be set ON or OFF. (Note that multicasting may not be available with the firmware you received;...
704x480 640x480 640x360 352x240 640x480 640x480 320x240 640x360 640x360 320x240 352x288 352x288 352x240 352x240 320x240 320x240 4.2.2 V992D-IR This section allows you to adjust various V992D-IR settings. This section allows you to adjust various V992D-IR settings. Exposure Control Exposure Mode...
Page 16
Day & Night Mode Auto/Day/Night Set this filter to OFF to allow the V992D-IR to 'see' infrared light, removing the IR cut filter, when using an IR illuminator. This will make the image clearer. If set to Auto, the V992D-IR will automatically switch between IR cut filter On and Off, according to the current lighting conditions.
Determines (0 ~ 90) x 1/30 sec (0 ~ 3sec) Viewer OSD Setup Date: Determines whether the date is displayed. Resolution: Determines whether the V992D-IR resolution is displayed. Event State: Determines whether the event state is shown on display window (M for motion is shown in Live View).
Page 18
Select the Area and Color for the mask and use the mouse to drag the cursor to fill the area to be set as a Privacy Mask. Click Save and then click the Live tab on the top to confirm the Privacy Mask satisfies preferences and/or requirements.
FTP transmission by inserting the IP address, Port, Username and Password of the remote FTP Server. 4.4.2 Event Event FTP Sending You can configure the V992D-IR to upload still images to FTP server based on event such as Motion detection.
Directory The name of the directory where the still images will be stored when an Event occurs. File Prefix You may add a file name prefix to the stored image file name. Example: If the file prefix is ‘MVD’, the still image would be saved as MVD_date_time.jpg. FTP Send Mapping Choose which types of events will be recorded to the FTP server by checking the desired event.
Interval It allows for saving still images based on frequency (1 image every 10 sec, for example). Use the drop-down control to set from 10 seconds to 1 hour. Effective Period This parameter lets you decide whether to save still images at all hours of the day, or during specific times of the day.
4.5.2 Mapping Event Mapping It is possible to define conditions that would cause the V992D-IR to respond with certain actions. A triggered event happens as a result of an event that is mapped within this menu. This could be caused by motion detection.
Page 23
NOTE: IP address assignment via DHCP may lead to the situation where the IP address changes and you lose contact with the V992D-IR. If your DHCP server can update a DNS server, you can access the V992D-N4 by a static host name, regardless of having a dynamic IP address.
“Yes” from the pop-up window. 4) Check the Type as Static or DHCP from the list. When you double-click the V992D-IR within the list, the default web browser (Internet Explorer or compatible equivalent) will open and automatically connect to the V992D-IR.
You must turn Notification to ‘On’ and then enter the host names or addresses for your mail servers in the fields provided to enable the sending of event and error email messages from the V992D-IR to predefined addresses via SMTP. NOTE 1) Frequency: Mail server may register the sender to SPAM list if frequency is set to “1 Min”.
4.7.1 User When you access the V992D-IR, the Configure Root Password dialog box appears. Enter the default user name ADMIN and password 1234 to log in. To change the password or add a user, go to Setup > System > User. Fill in the User ID, Password and E-mail address.
To reset the V992D-IR back to the original factory default settings. Firmware Update From time to time, CBC will release firmware updated for the PixelPro Series V992D-IR, which will contain feature additions and other improvements. Always read the upgrade instructions and release notes that accompany each new firmware release, before updating the firmware.
Page 28
NOTE: Do not disconnect power to the unit during the upgrade. The unit will restart automatically after the upgrade has completed (1~5 minutes). 4. If you suspect the firmware upgrade for the V992D-IR has failed, always wait at least 5- 10 minutes before restarting the upgrade process.
Page 32
Underwriters Laboratories Inc. (“UL”) has not tested the performance or reliability of the security or signaling aspects of this product. UL has only tested for fire, shock or casualty hazards as outlined in UL’s Standard(s) for Safety, UL60065. UL Certification does not cover the performance or reliability of the security or signaling aspects of this product. UL MAKES NO REPRESENTATIONS, WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT.
Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.
“autopan” or “tour” modes of operation. Such continuous operation is outside the scope of this warranty. Any product sold as “special” or not listed in Vicon’s commercial price list: One year from date of original retail purchase.
Need help?
Do you have a question about the V992D-IR and is the answer not in the manual?
Questions and answers