5. System Setup and Operation

How to Load the Saved Parameter

How to Load the Saved Parameter
Save user mode to the customer for different scene directly call, leave out
the edit operation inconvenience, VSP 5360 provides 13 save preferences.
Push LOAD button, the key lights, OLED shows related load information,
operate according to the prompt information.
Some of the number buttons 0-12 in PRE area are on, some flash and
some are off. The buttons on mean there are save information. OLED
shows as follows:
Push the button on to load, for example, button 1, OLED shows as follows:
VSP 5360
PUSH THE LEDS ARE ON TO RECALLLED
Button on is ready for recall
Button flashes means just recall
RECALL USER CONFIG MODE 1
RECALL IS SUCCESSFUL
INPUT:CV2