Compressed Air Filter - Pro Spot PR-111 Instruction Manual

Inverter plasma cutter series
Table of Contents

Advertisement

UNIT
Keep the cutting or gouging area and the area around the machine clean and free of combustible
materials. No debris should be allowed to collect , this could obstruct air ow to the machine.
Inspect the unit every 3-4 months (depending on how often the unit is used) and use compressed air
to remove any dust deposits.
Only use dry compressed air for cleaning. Do not point the jet of air at the electronic circuits.
TORCH
Periodically, according to its use or to cutting faults verify wear of the parts connected to plasma arc:
Shield Cup:
Unscrew manually from head of the torch. Clean throughly abd replace if damaged (burns, distortions or
cracks). Verify integrity of superior metal sector (actuator torch safety).
Tip:
Check wear of plasma arc hole and of inner and outer surfaces. If the hole is widened compared to its
original width or if it is damaged, replace tip. If surfaces are particularly oxidated clean them with extra
ne abrasive paper.
Air Distribution Ring:
Verify the are no burns or cracks or that air ow holes are not obstructed. If damaged, replace immediately.
Electrode:
Replace electrode when crater settling on emitting surface is about 2mm.
WARNING!
Before making any operation to the torch let it cool at least all along the "postgas" period.
Except for particular cases it is advisable to replace electrode and tip AT THE SAME TIME.
Respect assembly order of torch parts (reserved compared to disassemblage).
Be carefull that distributing is assembled properly.
Reassemble shield cup screwing tightly and manually.
Never assemble shield cup without having assembled electrode distributing ring and tip befo-
rehand.
Timely and appropriate control procedures on torch parts are essential for safety and functionality of
the cutting system.
TORCH BODY, HANDLE AND CABLE
These parts usually need no particular maintenance with the exception of a periodic inspection and
an accurate cleaning to be made WITHOUT THE USE OF SOLVENTS.
In case of damages to the insulation such as breaks, cracks and burns or even a loosening of electric
coonductors, the torch CANNOT BE USED FURTHER SINCE SAFETY CONDITIONS HAVE NOT
BEEN RESPECTED.
IN THIS CASE, REPAIRING (EXTRAORDINARY MAINTENANCE) CANNOT BE MADE ON SITE
BUT NEEDS TO BE DELEGATED TO A SERVICE CENTER TO MAKE SPECIAL REST TRIALS
AFTER REPAIRING HAS BEEN EXECUTED.
In order to keep the torch and the cable ef cient it is necessary to follow these precautions:
DO NOT touch torch and cable with warm or hot parts.
DO NOT strain the cable.
DO NOT move the cable on sharp edges or abrasive surfaces.
gather the cable in regular coils if it is too long.
DO NOT step on the cable.

COMPRESSED AIR FILTER

The unit is equipped with a lter for the compressed air. This lter is tted with a knob for the ma-
nual drain of the condensation. Purge periodically to remove the water/oil in the lter by following
the instructions of paragraph "Compressed air".
24
CAUTION!

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pr-112Pr-113

Table of Contents