PIR Movement Detector not detecting a
person's movement.
1. Ensure the battery clip is securely connected.
2. Ensure 'ID code' of the Detector has been learnt
by the Siren (see page 18).
3. Sensitivity set too LOW - reset to HIGH
sensitivity, (i.e. SW3 to up position).
4. Ensure that detector is mounted the correct way
up, (i.e. with detection window at the bottom).
5. Ensure that the detector is mounted at the
correct height, (i.e. 2 - 2.5 metres).
6. Once the system is armed allow up to 3 minutes
for the detector to stabilize and become fully
operational. Leave the area for this period.
If the system is armed with a delay allow a
further 15 seconds to ensure that the Entry
delay period has expired.
7. Ensure detector is within effective radio range
of the Siren and is not mounted close to metal
objects which may interfere with the radio
transmission.
PIR Movement Detector LED flashes on
detection of movement, (device in Normal
Operation Mode).
1. Low battery - Replace battery.
2. PIR still in Walk Test Mode for fixed 5 minutes if
the PCB button was activated (see page 15).
Door / Window Detector not working.
1. Ensure that Magnet is correctly positioned in
relation to Detector and that the gap between
magnet and detector is less than 10mm.
2. Ensure batteries are fitted with correct polarity.
3. Ensure battery holder connections are making
good contact with the batteries and PCB
(Circuit board).
4. Ensure 'ID code' of the Detector has been learnt
by the Siren.
5. If there is no additional wired Magnetic Contact
connected ensure switch SW3 is set to (INT.)
internal contact ON.
26
6. If an additional wired Magnetic Contact is
connected:
a. Check that both contacts are closed.
b. Check that additional contact is correctly wired
and switch SW3 set to the INT./EXT. position.
Note: If a wired contact is used, both protected
doors / windows must be closed when the system
is armed (otherwise neither door / window will
be protected).
7. Ensure detector is within effective radio range
of the Siren and is not mounted close to metal
objects which may interfere with the radio
transmission.
Door / Window Detector false alarming.
1. Ensure that Magnet is correctly positioned in
relation to Detector.
2. Ensure that gap between Magnet and Detector
is less than 10mm.
3. Tamper switch below battery cover not
depressed - check battery cover is fitted
correctly and that fixing lugs are not broken.
LED on Door / Window Detector illuminating
when door or window is opened.
1. Low battery - replace batteries.
CUSTOMER HELPLINE
Most issues can be solved over the
phone in a few minutes.
Please contact our Helpline Team on
the number below for any installation
and general advice regarding our
products:
0844 736 9149
Lines open 9.00am to 5.00pm, Monday to Friday.
Calls charged at service providers national rate.