Wiring The Antenna Unit Power Cable; Figure 2-18 Antenna Data Cable Wiring Arrangement; Figure 2-19 Proper Terminal Strip Wiring Arrangement - Power Cable - KVH Industries TracVision S3 Owner's Manual

Tracvision s3
Hide thumbs Also See for TracVision S3:
Table of Contents

Advertisement

2.3.2 Wiring the Antenna Unit Power Cable

TracVision S3 will not function properly unless you connect the
power cable (Cable #32-0590-30).
Power Cable-to-Baseplate Terminals Wiring Process
1. Feed the cable up to the roof and through the
fourth liquid-tight fitting (#4) from the left as
pictured previously in Figure 2-14.
2. Refer to Figure 2-19 for the proper arrangement of
power cable wires within the terminal strip.
3. After connecting the power cable to the
TracVision S3, hook up the other end to the
switchplate as described in the next subsection.
54-0182 Rev. A1
Figure 2-18
Antenna Data Cable Wiring
Arrangement
BLU/WHT
Not Used
WHT/BLU
Not Used
BRN/WHT
PC GND
WHT/BRN
PC TXD
ORG/WHT
PC RXD
Data Cable
WHT/ORG
RF GND
to Antenna
GRY/WHT
RF TXD
WHT/GRY
RF RXD
GRN/WHT
Not Used
WHT/GRN
Not Used
Figure 2-19
Proper Terminal Strip Wiring
Arrangement – Power Cable
Shield
Red
Black
Brown/White
Orange/White
White/Brown
White/Orange
White/Gray
Gray/White
Shield
Installation
1
Grnd
2
+12v DC
3
Grnd
4
RTN
5
PC_RXD
6
PC_TXD
7
RTN
8
RF_TXD
9
RF_RXD
10
Grnd
2-11

Advertisement