Mercedes-Benz E-Class BR 211 / CLS BR 219
1
3
1
3
2
1
1
Preparing the Heater Unit
Place the solenoid valve and bracket
on the stay bolts in the heater unit and
fasten with the flanged nuts.
Fasten the preassembled coolant hose with
the spring band clamp to the solenoid valve.
Replace the connector on the solenoid valve.
2
1 Solenoid valve connector
2 Preassembled coolant hose with clamp
3 M6 flanged nuts [3x]
4
Connect the mecanyl fuel line to the heater
fuel line nipple with the
hose section and clamp.
1 Fuel line
2 Universal clamp
(white color identification) [2x]
3 Hose section
2
5
Installing the heater unit
Loosely pre-assemble the solenoid valve
bracket on the wheel well
with two screws.
1 M6x12 collar screws [2x]
2 Solenoid valve bracket
6
Loosely pre-assemble the heater unit
2
bracket on the bumper cross member with
two screws.
Tighten all fastening bolts.
Plug the wiring harness connector into the
heater.
Route the wiring harness to the right
suspension strut mount.
1 M6x12 collar screws [2x]
2 Heater unit bracket
7
Connect-
ing the
solenoid
valve
Connect-
ing
the fuel
line
Installing
the
solenoid
valve
Assembl-
ing the
heater unit
7