i.
Shut off unit. Remove jumper wire from wire harness connector and plug the
connector into seat switch. Remove unit from supports.

5.2.10 Neutral Switch Adjustment

a. The two neutral switches are located between the two hydraulic pumps
located under the seat. These are non-contact magnetic switches.
Neutral
Sensors
b. The switches sense neutral and will not allow the machine to start if the
machine is not in neutral.
Formula - 20071
Maintenance & Adjustment
Magnets
39