Jumper Settings - Emerson MVME51005E Installation And Use Manual

Table of Contents

Advertisement

1 Hardware Preparation and Installation
Table 1-1. Manually Configured Headers/Jumpers (continued)
Jumper
J7
J10, J17
J15
J16
Refer to the section titled Jumper Settings on the next page for additional information.
Note
1. Write protects only outer two 8K boot sectors. Refer to
an complete explanation.

Jumper Settings

Prior to performing the installation instructions, you must ensure that the jumpers are set
properly for your particular configuration. For example, if you are using an IPMC761/MVME761
or IPMC712/MVME712 combination in conjunction with the MVME5100, you must reset the
jumpers for the SBC mode (jumpers J4, J6, J10, J17 and J20). These are factory configured for
the PMC mode. Verify all settings according to the previous table and follow the instructions
below if applicable.
4
MVME51005E Single Board Computer Installation and Use (6806800A38B)
Description
Flash Memory Selection
Ethernet Port 2
Selection
(see also J4)
System Controller
(VME)
Soldered Flash
Protection
Setting
Pins 1, 2 for Soldered Bank A
Pins 2, 3 for Socketed Bank B
For Front Panel Ethernet Port 2:
Pins 1, 3 and 2,4 on Both Jumpers
For P2 Ethernet Port 2:
Pins 3, 5 and 4, 6 on Both Jumpers
(set for SBC mode)
Pins 1, 2 for No SCON
Pins 2, 3 for Auto SCON
No Jumper for ALWAYS SCON
Pins 1, 2 Enables Programming of
Flash
Pins 2, 3 Disables Programming of
the upper 64KB of Flash
Default
Sockete
d
Bank B
Front
Panel
Ethernet
Port 2
Auto
SCON
Flash
Prog.
Enabled
1
Flash Memory on page 40
for