Conversion Instructions
Gas Conversion
How To Remove Range For Servicing
Follow these procedures to remove appliance for
servicing:
1. Shut off gas supply to appliance.
2. Disconnect electrical supply to appliance, if equipped.
3. Disconnect gas supply tubing to appliance.
4. Slide range forward to disengage range from the
anti-tip bracket.
5. Reverse procedure to reinstall. If gas line has been
disconnected, check for gas leaks after reconnection.
NOTE: A qualified servicer should disconnect and
reconnect the gas supply.
The servicer MUST follow installation instructions
provided with the gas appliance connector and the
warning label attached to the connector.
6. To prevent range from accidentally tipping, range must
be secured to the floor by sliding rear leveling leg into
the anti-tip bracket.
Service - Parts Information
When your range requires service or replacement parts,
contact your dealer or authorized service agency. Please
give the complete MODEL and SERIAL numbers of the
range which is located on the range model number plate.
©2004 Maytag Services

(Model CPR1100AD*)

General
All ranges are equipped with fixed orifices and with a
convertible appliance pressure regulator. The unit model
number plate states which gas it was adjusted for at the
factory. To convert the unit to either Natural Gas or LP
Gas will require replacement of the orifice hoods,
adjustment of the air shutters on the burners and
adjustment of the appliance pressure regulator converter
cap or plunger.
Inlet pressure to the appliance pressure regulator should
be as follows for both operation and checking of appliance
pressure regulator setting:
INLET PRESSURE IN
INCHES OF WATER COLUMN
Minimum
Maximum
Appliance Pressure Regulator Conversion
The unit appliance pressure regulator must be set to
match the type of gas supply used. If converting from
Natural Gas to LP Gas, the appliance pressure regulator
must be converted to regulate LP Gas. If converting from
LP Gas to Natural Gas, the appliance pressure regulator
must be converted to regulate Natural Gas.
To Convert The Appliance Pressure
Regulator From One Gas To Another:
Remove cap, turn converter cap or plunger over and
replace cap. (See figure 1).
NOTE: What you read on the converter cap or plunger
after conversion is the type gas setting for that regulator,
i.e. If you read NAT. the regulator is set for Natural Gas.
16023522
NATURAL
GAS
5
14
LPG
NAT
FIGURE 1
LP
GAS
11
14
8101P635-60