Westermo OnTime T200 series Installation Manual

Ontime industrial ethernet
Hide thumbs Also See for OnTime T200 series:
Table of Contents

Advertisement

Quick Links

V3.8
U/R/T200 series Installation Guide
..............................................................................................................................................
OnTime Industrial Ethernet
U/R/T200 series Installation Guide
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for Westermo OnTime T200 series

  • Page 1 V3.8 U/R/T200 series Installation Guide .............................. OnTime Industrial Ethernet U/R/T200 series Installation Guide - 1 -...
  • Page 2 V3.8 OnTime Industrial Ethernet U/R/T200 series Installation Guide - 2 -...
  • Page 3: Table Of Contents

    IEEE1588 T ....................- 30 - RANSPARENCY SNTP ..............- 30 - TIME CLIENT AND SERIAL TIME SERVER IRIG-B..........................- 31 - ................- 31 - ULSE SECONDS ON INTERFACE ......................- 31 - ULSE INUTE OnTime Industrial Ethernet U/R/T200 series Installation Guide - 3 -...
  • Page 4 SOFTWARE VERSIONS OF THE R/T200 SWITCH............- 42 - ........................- 42 - NTRODUCTION ........- 42 - OW TO UPGRADE FROM OLD TO NEW MAJOR SOFTWARE VERSION – ...............- 44 - CONFIGURATION TOOL SOFTWARE VERSIONS OnTime Industrial Ethernet U/R/T200 series Installation Guide - 4 -...
  • Page 5: Introduction

    This Operator Manual describes the properties of the T200, R200 and U200 series. 1.1 T200 The T200 is the time synchronization switch series of Westermo OnTime. The T200 series has also full management support including QoS, network redundancy (FRNT protocol), SNMP, IGMP snooping, VLAN and MAC security.
  • Page 6: Quick Install Guide

    Extract the .ZIP file to your computer, and start the application from a PC on the network that you want to configure. Make sure that the IP Address of the configuration software (see figure below) is in the same sub domain as your PC. OnTime Industrial Ethernet U/R/T200 series Installation Guide - 6 -...
  • Page 7 3. Assign an IP address for the configuration software. Ensure the address range is within the same Subnet as your assigned IP address for your PC. 4. Press the ‘Scan for devices’ button. The Switches on the network will be listed, see below. OnTime Industrial Ethernet U/R/T200 series Installation Guide - 7 -...
  • Page 8 18. Press the ‘Restart’ button to re-configure the Switch. The Switch will run through the start sequence. During this period communication to the Switch will be lost. 19. Continue connecting Switches in this manner until the ring has been completed OnTime Industrial Ethernet U/R/T200 series Installation Guide - 8 -...
  • Page 9: Switch Installation And Configuration

    Detailed drawings for both vertical (MOUN0004) and horizontal (MOUN0002) DIN rail mounting are found on http://www.OnTimenet.com/downloads.htm. Heavy duty DIN clips are also available (improved vibration properties) for horizontal DIN rail mounting, MOUN0003. This mounting kit must be ordered separately. OnTime Industrial Ethernet U/R/T200 series Installation Guide - 9 -...
  • Page 10: 19" Dual Units Mounting

    Figure 2 shows how to mount two URT200 by using the 19” dual units mounting kit. This mounting kit must be ordered separately. Figure 2, 19” dual units mounting kit OnTime Industrial Ethernet U/R/T200 series Installation Guide - 10 -...
  • Page 11: 19" Single Unit Mounting

    Figure 3 shows how to mount on U/R/T200 by using the 19” single unit mounting kit. This mounting kit must be ordered separately. Figure 3, 19” single unit mounting kit OnTime Industrial Ethernet U/R/T200 series Installation Guide - 11 -...
  • Page 12: Wall Mounting

    4 x nut brackets 8 x brackets 8 x screws Figure 4 shows how to mount the wall mounting kit. This mounting kit must be ordered separately. Figure 4, Wall mounting kit OnTime Industrial Ethernet U/R/T200 series Installation Guide - 12 -...
  • Page 13: Power Connection

    Power supply inputs have reverse polarity protection. The switch is delivered with a power connector (Wieland 25.621.3553.0) that is suitable for wires between AWG 20 and AWG 22 (0,34-0,5 mm OnTime Industrial Ethernet U/R/T200 series Installation Guide - 13 -...
  • Page 14: Fault Contact

    The LED/push button panel is shown in the figure below. Figure 7, LED’s and push buttons OnTime Industrial Ethernet U/R/T200 series Installation Guide - 14 -...
  • Page 15: Normal Indication Mode

    Newly configured settings are stored in non-volatile memory when the Save button is pressed. Note: Manual configuration of fiber ports is not possible. These ports are configured for full duplex connectivity and 100 Mbps. OnTime Industrial Ethernet U/R/T200 series Installation Guide - 15 -...
  • Page 16: Led Fault Indication

    When the fault contact is energised the front panel display will also mimic this status by strobing one or more the above LEDs. When the fault(s) is cleared the LEDs will automatically be extinguished. Figure 8, LED’s and push buttons OnTime Industrial Ethernet U/R/T200 series Installation Guide - 16 -...
  • Page 17: Fiber Optic Care

    Keep hands clean when touching fiber optic cable. • Patch cables should be cleaned with IPA and dried with a lint-free cloth before installation. • Once patch cables have been installed dust will not ingress the transceiver OnTime Industrial Ethernet U/R/T200 series Installation Guide - 17 -...
  • Page 18: Ip Configuration Software

    V3.8 4 IP Configuration Software The Westermo OnTime Switches are configured using supplied software. The program is available for download from OnTime web page: http://www.OnTimenet.com/upgrade.htm. Extract the .ZIP file to your computer, the application is called IP configuration. Start the application from a PC on the network. Make sure that the IP Address of the configuration software (see figure below) is in the same sub domain as your PC.
  • Page 19 Address • Firmware Revision • Configuration Style • Ring Status Figure 10 By clicking on the line for each respective switch, further configuration opportunities will appear. See below. Figure 11 OnTime Industrial Ethernet U/R/T200 series Installation Guide - 19 -...
  • Page 20 BUS. An exclamation mark will be shown on the ports that have lost connection. • Scanning For Devices Highlights All Switches On Ring • Ring Failure Occurred • FP Now Running As Bus • Highlights Link / Port That Have Failed Figure 13 OnTime Industrial Ethernet U/R/T200 series Installation Guide - 20 -...
  • Page 21 Figure 14, FRNT v1 Multiple ring configuration By clicking the “port config” button in the “Port configuration” setup dialog box will appear, see Figure 15. See chapter 4.10 for more details. Figure 15, Port configuration setup OnTime Industrial Ethernet U/R/T200 series Installation Guide - 21 -...
  • Page 22 By clicking the “VLAN” button in the “VLAN configuration” setup dialog box will appear, see Figure 16. The VLAN tick box must be enabled before the VLAN button is enabled. See chapter 4.12 for more details. Figure 16, VLAN configuration setup OnTime Industrial Ethernet U/R/T200 series Installation Guide - 22 -...
  • Page 23: Frnt Version 0 - Single Ring

    37. Press the ‘Restart’ button to re-configure the Switch. The Switch will run through the start sequence. During this period communication to the Switch will be lost. 38. Continue connecting Switches in this manner until the ring has been completed OnTime Industrial Ethernet U/R/T200 series Installation Guide - 23 -...
  • Page 24: Frnt Version 1 - Multiple Rings

    IP configuration tool by ticking the ‘Enable redundant bridge function’.. 6. Define which port that will act as the ‘FRNT enabled port’ in the ‘advanced’ dialog box. Connect this to the other FRNT v0 ring. OnTime Industrial Ethernet U/R/T200 series Installation Guide - 24 -...
  • Page 25: Rstp/Stp

    SNMP traps can be generated by the R/T200 switch and sent to the NMS. This is done by setting the address in the Westermo OnTime private MIB part eneral/trapHostAddr. The SNMP TRAP is sending TCP/UDP packets on port 162.
  • Page 26: Dhcp

    To enabled the monitoring of the temperature in the switch - use the tempAlarm trap. OnTimenet/switch/fs200/tempAlarm/tempTrapEn. The switch sends a SNMP TRAP when the temperature has raised the predefined limit. The Trap host address is set by the Westermo OnTime private Management Information Base MIB) general part.
  • Page 27: Ip Gateway Address

    Only one sniff port and one mirror port can be defined. Ethereal or similar network capture programs can be used for OnTime Industrial Ethernet U/R/T200 series Installation Guide - 27 -...
  • Page 28: Igmp Snooping

    Additional VLANs per port. The VLAN id’s is by default as follows White VLAN id Red VLAN id Blue VLAN id OnTime Industrial Ethernet U/R/T200 series Installation Guide - 28 -...
  • Page 29 This property has the following practical impact on the IP configuration tool: the user must type “Scan for switches” a few times before the complete switch list will appear. OnTime Industrial Ethernet U/R/T200 series Installation Guide - 29 -...
  • Page 30: Time Synchronization

    5 Time synchronization The T200 can be enabled for time synchronization by ticking the “Enable time sync” box. This box is only available on the T200 switches (i.e. Westermo OnTime switches with hardware level time stamping support). Press the ‘Set’ button and then the ‘Reset’ button to restart the Switch after any changes performed on the time synchronization parameters.
  • Page 31: Irig-B

    IEEE1588 Grand master. Configuration of these two signals, OUT 1 and OUT 2, is done via SNMP. The following parameters in the timesync group of the private MIB of Westermo OnTime can be set: tsOut1Config [low, IRIG-B, PPX, high] tsOut2Config [low, IRIG-B, PPX, high]...
  • Page 32 Port A RS-422 Positive receive 8/Green Port A RS-422 TX- Port A RS-422 Negative transmit 9/Black Ground Negative DC power / ground 10/Blue Port A RS-422 TX+ Port A RS-422 positive transmit OnTime Industrial Ethernet U/R/T200 series Installation Guide - 32 -...
  • Page 33 Phone: (909) 765-2200 Fax: (909) 922-1544 Or Westermo OnTime networks provide cables that are pre-assembled in the Acutime end and that is sealed and sufficient for outdoor installations. The following standard cable lengths are available: 15, 30, 60 and 120 m...
  • Page 34: Serial Time Server

    A termination resistor (120 Ohm) shall be mounted in the connector between the positive and negative conductor. Return procedure Contact your equipment supplier before returning any equipment. Equipment will not be accepted without an RMA number. OnTime Industrial Ethernet U/R/T200 series Installation Guide - 34 -...
  • Page 35: Upgrading Of The R/T200 Switch

    Find the FTP Service in the service list, right click on it and choose stop. 8.2.2 Configure the FTP server 1. Start the FTP Server distributed with the upgrade file. 2. Go to Security -> Users/rights (See fig.) OnTime Industrial Ethernet U/R/T200 series Installation Guide - 35 -...
  • Page 36 3. Type in User Name anonymous, Set Home directory to C:\ (see figure below) 4. Click done. 5. Go to Security->General. (see figure below) 6. Fill in the dialog box as shown below. 7. Go to Logging->Log Options (see figure below) OnTime Industrial Ethernet U/R/T200 series Installation Guide - 36 -...
  • Page 37: Firmware Upgrade Via Ip Configuration Tool

    Make sure that the PC, the IP configuration tool and the switches that are to be upgraded are in the same IP sub net. Copy the .bin file (delivered by Westermo OnTime Networks) to the FTP-server directory on the PC (default c:\, see above).
  • Page 38: Ftp Server Troubleshooting

    See the examples below if the upgrade procedure described in chapter 8.3 was not successful. Start an FTP server on the PC where you will run Westermo OnTime IP Configuration tool to upgrade an Westermo OnTime switch. The FTP server must allow anonymous logins. The best way to test the FTP server itself is to run an FTP client session on the same PC.
  • Page 39 01/14/05 10:50:45 RETRieve started on file vx240.bin 01/14/05 10:50:46 Transfer finished 01/14/05 10:50:46 Got file C:\H\IMAGES\vx240.bin successfully 01/14/05 10:50:50 Command "QUIT" received 01/14/05 10:50:50 QUIT or close - user anonymous logged out OnTime Industrial Ethernet U/R/T200 series Installation Guide - 39 -...
  • Page 40: Example 2

    01/14/05 10:56:29 Command "TYPE I" received 01/14/05 10:56:29 TYPE set to I N 01/14/05 10:56:33 Command "PORT 192,168,13,101,5,22" received 01/14/05 10:56:33 PORT set to 192.168.13.101 - 1302 (5,22) 01/14/05 10:56:41 Command "CWD c:/" received OnTime Industrial Ethernet U/R/T200 series Installation Guide - 40 -...
  • Page 41: Typical Problems

    If there are still problems when you try to upgrade the image through Westermo OnTime IP config, the next step is to repeat the above process from another PC in the local network. With the deployment of Windows XP Service pack 2 and various anti virus programs, the FTP access might be stopped in the firewall on your PC.
  • Page 42: Software Versions Of The R/T200 Switch

    (switches in green). The two rings are connected via the two focal points through a copper drop link (TX). One extra R/T200 switch is required in order to perform this upgrade procedure. OnTime Industrial Ethernet U/R/T200 series Installation Guide - 42 -...
  • Page 43 FOCAL POINT SWITCH MEMBER SWITCH MEMBER SWITCH FOCAL POINT SWITCH Step 3 MEMBER FOCAL POINT SWITCH SWITCH MEMBER SWITCH MEMBER SWITCH Step 4 MEMBER FOCAL POINT SWITCH SWITCH MEMBER SWITCH OnTime Industrial Ethernet U/R/T200 series Installation Guide - 43 -...
  • Page 44: Ip Configuration Tool - Software Versions

    The IP configuration tool version 7.x.x or newer can be used versus any managed switch from Westermo OnTime Networks. Switch control options for a given switch will be enabled based on the type of switch and software version running on the switch. This means that no separate release note exist for a new version of the IP configuration tool.

This manual is also suitable for:

Ontime r200 seriesOntime u200 series