void digHoutTriState(int channel, int state);
Sets the state of a high-current digital output (HOUT0–HOUT3) to a logic 0, logic 1, or high impedance.
Remember to call the brdInit and the digHTriStateConfig functions before executing this
function.
A runtime error will occur for the following conditions:
1. channel or state out of range.
2. brdInit or digHTritateConfig was not executed before executing digHOutTriState.
3. If you try to use a channel that is not configured as a tristate output by digHTriStateConfig.
PARAMETERS
channel is the output channel number (0–3).
state sets a given channel to one of the following output states depending on how the output was con-
figured by digHTriStateConfig.
Trisate configuration:
0 = connect the load to GND
1 = connects the load to +K(0–3)
2 = put the output in a high-impedance state
RETURN VALUE
None.
SEE ALSO
brdInit, digHout, digHOutConfig, digHTriStateConfig