3.2 Digital I/O

3.2.1 Digital Inputs

The BL2600 has 16 digital inputs, DIN16–DIN31, each of which is protected over a range
of –36 V to +36 V. The inputs are factory-configured to be pulled up to +5 V, but they can
also be pulled up to +K or DCIN, or pulled down to 0 V in banks by changing a jumper as
shown in Figure 7.
GND
Figure 7. BL2600 Digital Inputs DIN16–DIN31 [Pulled Up—Factory Default]
Table 2 lists the banks of digital inputs and summarizes the jumper settings.
Digital Inputs
DIN16–DIN19
DIN20–DIN23
DIN24–DIN31
When you use the software
are considered to be digital input channels 16–31.
14
DCIN
27 kW
100 kW
Table 2. Banks of BL2600 Digital Inputs
Header
Pins Jumpered
JP3
1–2
JP4
3–4
JP5
5–6
7–8
function call to read the digital inputs, DIN16–DIN31
digIn
+3.3 V
+5 V
+K
Rabbit 3000 ®
Microprocessor
Pulled Up/Pulled Down
Inputs pulled up to +5 V
Inputs pulled up to DCIN
Inputs pulled up to +K
Inputs pulled down to GND
Wolf (BL2600)