Z-World Wolf BL2600 User Manual page 46

C-programmable single-board computer with ethernet
Table of Contents

Advertisement

void digHOut(int channel, int state);
Sets the state of a high-current digital output (HOUT0–HOUT3) to a logic 0, logic 1, or high impedance.
Remember to call the brdInit and the digHOutConfig functions before executing this function.
A runtime error will occur for the following conditions:
1. channel or state out of range.
2. brdInit or digHOutConfig was not executed before executing digHOut.
3. If you try to use a channel that is configured as a tristate output by digHTriStateConfig.
PARAMETERS
channel is the output channel number (0–3).
state sets a given channel to one of the following output states depending on how the output was con-
figured by digHoutConfig.
Sinking configuration:
0 = connect the load to GND
1 = put the output in a high-impedance state
Sourcing configuration:
0 = put the output in a high-impedance state
1 = connects the load to +K(0–3)
RETURN VALUE
None.
SEE ALSO
brdInit, digHOutConfig, digHoutTriState, digOut
42
Wolf (BL2600)

Advertisement

Table of Contents
loading

Related Products for Z-World Wolf BL2600

Table of Contents