YES
check electric supply to
hob?
YES
Replace spark
generator
Faulty ignition (Automatic ignition)
Customer states no ignition to burner/s
Is more than one
burner affected?
YES
Are all four
burners affected
NO
Replace electrodes as
required andIgnition switch
(micro switch)
NO
Can you see a
spark at the burner?
NO
Replace
electrode and or ignition
switch ( micro switch)
YES
clean and make sure
burnerskirt and cap are
NO
fitted correctly.
If this does not work.