Wiring the Speaker, Mic., and Keypad/Display Assembly Multiple Entrances and Telephone Line wiring . Wiring to Earth Ground POWERING THE SYSTEM ELEVATOR-RECALL(RESTRICTION) FEATURE . PROGRAMMING INSTRUCTIONS FOR ADC Series CONTROLLERS: Scrolling Non-scrolling Entering Programming Mode . 21 Direct Access Programming Codes Table .
AC REN: 0.3B Notice for all ADC series Telephone Entry System Sold Internationally: Conformity to the local Tel. Co. standards must be reviewed before installation of ADC Series Telephone Access Systems. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems...
T Watch Dog Timer circuit to automatically reset the unit to eliminate system latch-up. T Voice Mail Access capability -the required digits can be entered through the entry panel’s keypad. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 2...
INTRODUCTION MIRCOM'S ADC Series Controllers provides a hands-free communication (handset optional) and security controls of devices such as electric door locks, camera, and garage door (auxiliary) in a multi-unit dwelling establishments. The system required a dedicated telephone line to operate. It can be configured for Multiple entrances with independent doors and camera activation function.
9508 Recall Elevator Recall Note A 4 PS-3B, FOR ELEVATOR RECALL RELAYS PS-3B, FOR ELEVATOR RECALL RELAYS NOTE A: 4 WIRES FOR RELAY CONTROL (22 AWG, 1 JACKET, SHIELDED) MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 4...
Magnetic strips directory kit, 40 names capacity. It comes with plastic letters, magnetic strips, brackets, and hexnuts. ± Model TH-101 Thermostat heater. Note: Painted Silver, Gold & Copper Vein lobby panels are available by custom order. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 5...
PC/XT/286/386/486/Pentium Compatible PC under MS-DOS version 5 or higher, Windows 95 or higher, OS/2 with Colour or Monochrome Text Screen (MDA, CGA, EGA, VGA, SVGA) capability and one serial port. To order this kit, please consult our factory for further information. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 6...
3. SYSTEM & DOOR RELEASE POWER REQUIREMENTS A single Mircom's PS-3B (Tri-Volt) power transformer is required to power the unit and lamps. A second power transformer is required to operate the door release. Please note that the transformer and the door release must be compatible.
ENCLOSURES AND ACCESSORIES INSTALLATION INSTRUCTIONS MOUNTING THE UNIVERSAL TYPE LOBBY/ENTRY PANEL Mount the panel as shown in FIG.1, FIG.2, and FIG. 2A using the supplied screws. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 8...
Page 11
BOTTOM VIEW MODEL NO. DIM. `A' DIM. `B' SEMI-FLUSH TRIM RING IF REQUIRED 11" 9 3/16" MODEL MUFT-5000P MUS-5000/H/S/SH, MUS-5024,MPD-5120 MODEL MUFT-5120P MUS-5120, MUS-5120H, MPD-5240 20 3/4" 18 15/16" MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 9...
Mount the Magnetic Letter Kit according to the Installation Instruction (LT-460) that comes with the Kit. Extra characters and magnetic strips can be ordered separately. Please contact the factory or our nearest dealer. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 10...
Use a pair of #18 AWG wires to connect from the TH- 101 unit to 24VAC tap on the PS-3B transformer. The transformer must be installed outside the enclosure. Fig. 2B HEATER INSTALLATION MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 11...
Page 15
MOUNTING THE MAGNETIC LETTER KIT MLK-070 (OPTIONAL) Mount the Magnetic Letter Kit according to the Installation Instruction (LT-460) that comes with the Kit. This kit is used only for Continental type lobby/entry panel. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 13...
SYSTEM WIRING INSTRUCTIONS WIRING THE DOOR STRIKE Wire the Door Strike as shown in FIG.4. WIRING THE ELECTROMAGNETIC DOOR LOCK Wire as shown in FIG. 5. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 14...
Wire the Lock-Back Switch as shown in FIG. 6 to enable automatic door-open timer cut-off. WIRING THE DOOR OVERRIDE (Postal Lock & Fire Alarm) Wire as shown on FIG.7. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 15...
WIRING THE AUXILIARY RELAY and MAIN ENTRANCE ACTIVE RELAY CONTACTS Wire as shown in FIG.8. WIRING THE SYSTEM and LAMP SUPPLIES Wire as shown in FIG. 9. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 16...
WIRING THE EARTH GROUND - IMPORTANT NOTICE: Although the electronics of the ADC Series are not Earth Grounded, it is absolutely vital to have good solid Earth Grounding connections to each enclosure; that is, a ground bonding wire (preferably at least 14 AWG) that is run to the NEAREST confirmed building electrical system ground, or cold water pipe.
ELEVATOR-RECALL(RESTRICTION) FEATURE GENERAL OPERATION Elevator-Recall(Restriction) is now a standard feature which has been implemented in the ADC Series system for software version 3.0 and up. The feature operates as such: a visitor calls a resident, is then allowed entrance at which point the entry door is opened and the floor relay is activated.
Page 21
NOTE: FIRST TWO DIGITS OF THE RESIDENT/TENANT CODE REPRESENTS THE ELEVATOR- R E C A L L RELAY NUMBER. WHEN USING ELEVATOR-RECALL (RESTRICTION) IT IS NECESSARY TO USE A SEPARATE TIMER FOR EACH OF THE FLOOR RELAYS. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 19...
Page 22
Wiring is achieved at the terminal block which is removable for easy installation. The following diagram shows the wiring between the ADC Controller and the Elevator Restriction (Recall) Relay Cabinet motherboard. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 20...
Page 23
*5*5 while at Program Mode menu . Since this special command (*5*5) is a destructive command which can erase all the programmed information without the provision to undo, the user must take a precaution when using this command. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 21...
Page 24
*808 Set On Line Timer 60 seconds __ __ 00 to 99 (2 digits) *909 Select MULTIPLE/SINGLE Entrance Single (11) __ __ 11 Single or 00 Multi (2 digits) MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 22...
Page 25
Telephone Numbers. SETTING THE TELEPHONE NUMBER DIGIT LENGTH: Scroll through until you reach the feature as shown below. [1=Bck] [3=Fwd] Do you want to edit Max. Digit/Listing? [*=Abort] [#=Yes] MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 23...
Page 26
Press # to store or * to abort entry. Repeat this process to edit or to assign new prefix numbers. To exit to Normal Mode, enter *000 while at the PROGRAM MODE menu. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 24...
Page 27
As mentioned previously, the user must set the Code and Prefix number when 9 to 11-digit telephone numbers are required. The following example will illustrate how the unit should be programmed. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 25...
Press * or # to scroll (review) "up or down" the list . To enter, review, edit and delete the Resident’s/Tenant’s name, scroll until the desired Access Code and Resident Name is in the second line of the display. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 26...
Page 29
-Program Options- #=Store, *=Abort Code # x x x x Please enter choice: Press # to store or * to abort entry. Repeat this process until all codes are entered. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 27...
Page 30
Enter the New Master Code. Please do not use *888 for Master Code. The next display should appear... -Program Options- #=Store, *=Abort * x x x Please enter choice: MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 28...
Page 31
( x ) Please enter choice: Press # to store or * to abort entry. To quit, enter *000 while at the PROGRAM MODE menu to return to NORMAL MODE. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 29...
Page 32
-Program Options- Press To exit Please enter choice: Press * to exit to PROGRAM MODE menu. To quit, enter *000 while at PROGRAM MODE menu to return to NORMAL MODE. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 30...
Page 33
Press # to store or * to abort entry. Press * to exit to the PROGRAM MODE menu. To quit, enter *000 while at the PROGRAM MODE menu to return to NORMAL MODE. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 31...
Page 34
Program the system as shown... -Program Options- Code: 2 8 6 3 9 - 0 5 6 - 6 0 4 - 6 5 5 . Please enter choice: MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 32...
Page 35
[*=Abort] [#=Yes] Press # to access the feature. The display should appear... -Program Options- Minutes or seconds M=11 S=00 _ _ <== Factory default is 00 Please enter choice: MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 33...
Performing copy . . . - Please Wait - When finished, the system should exit to PROGRAM MODE menu. To quit, enter *000 while at PROGRAM MODE menu to return to NORMAL MODE. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 34...
Program Choices *000 Exit Programming Mode *000 NONE *101 Enter Resident Code and Blank See worksheet 4 digit resident Telephone # code and up to 8 digit telephone number MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 35...
At this menu, pressing * will lead you to the PROGRAM MODE menu. Pressing # will exit to NORMAL MODE. Press 3 again for next menu. The next screen should lead you to the first feature menu. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 36...
Where: “Code” (from 0 to 9) is used to call up the corresponding Prefix number. “Prefix #” (up to 4 digits) is used for “Area Code” number that can be used with standard MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 37...
As mentioned previously, the user must set the Code and Prefix number when 9 to 11-digit telephone numbers are required. The following example will illustrate how the unit should be programmed. Example: Ten digits telephone number is required. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 38...
5000 to 9999. The user is advised to program the unit using these specified ranges if such operation is required. [Operation: To open door, press # followed by the four digits Keyless Entry Code] MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 39...
To change the MASTER CODE, scroll through until you reach the feature as shown below. To Change MASTER Code - Press # Press # to access the feature. The display should appear... MASTER CODE *_ _ _ MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 40...
( x ) Press # to store or * to abort entry. To quit, enter *000 while at PROGRAM MODE menu to return to NORMAL MODE. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 41...
To change Door-Open Timer (factory default is 10 seconds), scroll through until you reach the feature as shown below. Adjust Door-Open Timer - Press # Press # to access the feature. The display should appear... MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 42...
Press # to store or * to abort entry. The next display should appear... Press To Exit Press * to exit to PROGRAM MODE menu. To quit, enter *000 while at PROGRAM MODE menu to return to MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 43...
Press # to store or * to abort. The next display should appear ... Press * To Exit Press * to exit to PROGRAM MODE menu. To quit, enter *000 while at the PROGRAM MODE menu to return to NORMAL MODE. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 44...
REMOTE PROGRAMMING THE ADC NON-SCROLLING DIRECTORY USING DTMF Mircom provides remote programming functions such as: entering, reviewing and deleting of resident codes, telephone numbers and keyless codes. To perform this function a telephone capable of generating a “Touch Tone” or DTMF (dual tone multi-frequency) signal is required.
Page 49
EXIT PROGRAMMING MODE To exit from programming mode dial *000. If you do not use the exit code and hang up the telephone, the system will automatically disconnect after 2 minutes. MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 47...
IS62C256-70W ISSI SWITCH C2420900SL DOOR OVER- RIDE LOCK BACK S1 S2 M1 M2 12V T1 T2 T5 T3 T4 L1 L2 L3 L4 T6 T7 L5 L6 TO DISPLAY MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 48...
Page 51
DISPLAY CONTRAST ADJUSTMENT Open the panel door and adjust the contrast control as shown on FIG. 14. Turn clockwise to increase contrast on the display. FIG.14: DISPLAY CONTRAST LOCATION MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 49...
RESIDENT OPERATING INSTRUCTIONS Mircom's state-of-the-art door entry system has been installed in this building to provide you and your guest with an increased level of confidence and security. The system operates with your existing telephone. Your guest simply dials the code number next to your name on the entry panel directory and your telephone will ring.
Note: The unit will dial only after it detects a valid dial tone. Note: For further help, please call or fax: Application Engineering Department Tel.: (888) 660-4655 Fax: (888) 660-4113 MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 51...
1 1/4" Wide by 5 7/8" High by 1 1/2" Deep WEIGHT: 0.706 lb Model: M-20 VOLTAGE: 4-6V DC (silent), 8-16V AC (buzzing) DIMENSION: 1 3/4" Wide by 5 7/8" High by 1 1/2" Deep WEIGHT: 0.986 lb MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 52...
While at Resident Name Entry mode, scroll through the character set by pressing "1" to move backward or "3" to move forward. ex. while at 7, press "1" to go backward to 6. ex. while at c, press "3" to go forward to d. Space MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 54...
(1) year from the date of original shipment. MIRCOM will repair or replace, at its option, any equipment which it determines to contain defective material or workmanship. Said equipment must be shipped to MIRCOM prepaid.
Need help?
Do you have a question about the ADC Series and is the answer not in the manual?
Questions and answers