Display - SMA SUNNY TRIPOWER 6000TL Installation Manual

Pv inverter
Hide thumbs Also See for SUNNY TRIPOWER 6000TL:
Table of Contents

Advertisement

4  Product Description
4.4 Display
The display shows the current operating data of the inverter (e.g. current power, daily energy, total
energy) as well as events or errors. The power and energy are displayed as bars in the diagram.
M
L
Figure 6:
Display design (example)
Position
A
B
C
D
E
F
G
H
I
20
STP5-9TL-IA-en-10
kWh
I
K
Description
Power
Day
Total
Active functions
Line conductor
Event number relating
to the electricity grid
Output voltage/
output current
Event number relating
to the inverter
Input voltage/
input current
H
G
Explanation
Current power
Daily energy
Total amount of energy fed in until now
The different symbols indicate which functions for
communication, grid management or
temperature derating are enabled or active.
Indicates which line conductor the displayed
values are assigned to
Event number of errors relating to the electricity
grid
Displays output voltage and output current of a
line conductor in alternation
Event number of errors relating to the inverter
Displays input voltage and input current of
one input in alternation
SMA Solar Technology AG
A
kVAr
kW
B
kVArh
kWh
MVArh
MWh
C
D
E
F
Installation Manual