Cleaning Flow Restrictor - Watts Premier WP-5 Installation, Operation And Maintanance Manual

Table of Contents

Advertisement

Step 3
Pull firmly on the membrane to remove from the housing and
discard.
Unwrap new membrane and lubricate the o-rings with water soluble
Step 4
lubrication such as KY Jelly ® before inserting into housing. Insert
end with the two black O-rings into the cap. Twist the membrane as
you push firmly into the cap.
Step 5
Replace the vessel onto the cap by turning clockwise. Tighten
securely.
Cleaning the Flow Restrictor
Step 6
The flow restrictor plug (part no. 164015) must be cleaned each
time you change the Membrane (part no.110009.) Remove the
existing flow restrictor with a screwdriver.
Step 7
Wash with soap and water and rinse. Reinsert the flow restrictor
plug and tighten until the head is flush with module.
Step 8
Follow the Start Up Instructions on page 14.
Page 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wp5-50Kp-5B-ro5m-50

Table of Contents