Suspended Ceiling T-Bar Installation - Motorola AP-6521 Series Installation Manual

Hide thumbs Also See for AP-6521 Series:
Table of Contents

Advertisement

14
e. Attach the power supply line cord to a power supply.
10. Verify the behavior of the Access Point LEDs. For more information, see
11. The Access Point is ready to configure. For information on basic Access Point device configuration, see
Basic Access Point

2.5 Suspended Ceiling T-Bar Installation

A suspended ceiling mount requires holding the Access Point up against the T-bar of a suspended ceiling grid and
twisting the Access Point chassis onto the T-bar.
To install the Access Point on a ceiling T-bar:
1. If desired, install and attach a security cable to the Access Point lock port.
2. If using an external antenna model, attach the antennas to their correct connectors.
3. For more information on the antenna options available to the Access Point, see
4. Cable the Access Point using either the Power Injector solution or an approved line cord and power supply.
CAUTION
For Motorola Power Injector installations:
a. Connect an RJ-45 CAT5 Ethernet cable between the network data supply (host) and the Power
Injector's Data In connector.
b. Connect an RJ-45 CAT5 Ethernet cable between the Power Injector's Data & Power Out connector
and the Access Point.
c. Ensure the cable length from the Ethernet source (host) to the Power Injector and Access Point does
not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Power Injector
receives power as soon as AC power is applied. For more information, see
For power adapter (Part Number PWRS-147376-01R) and line cord installations:
a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply (host) and the
Access Point's GE1/PoE.
b. Verify the power adapter is correctly rated according the country of operation.
c. Connect the power supply line cord to the power adapter.
d. Attach the power adapter cable to the DC-48V power connector on the Access Point.
e. Attach the power supply line cord to a power supply.
5. Verify the behavior of the Access Point LEDs. For more information, see
Configuration
Configuration.
Do not connect to the power source until the cabling of the Access
Point is complete. Ensure PoE is not connected to the Access Point's
console connector or risk rendering the console connector
permanently inoperable.
.
AP-6521 Access Point
LED Indicator
.
Antenna Options
Power Injector System
Basic Access Point
.
.

Hide quick links: