Communication
List of data number related to communications
1) Communication parameter
Range of
Address Pr No. Parameter name
setting
80h(128)
8060h
60
Device number
to
9Fh(159)
Communication
8061h
61
0 to 2
speed
Communication
8062h
62
0 to 11
standard
Communication
8063h
63
10 to 1000
response time
Retry times of
8064h
64
0 to 9
communication
Default
Function/Description
Set the device number of amplifier in com-
munication (Amplifier ID).
This value is the axis number in communi-
cation.
80h (128) is the device number for setting
control data (such as control start) by one
81h(129)
operation to all connected amplifiers. (No
response is made by amplifier.)
When the device number is set to 80h (128),
change of parameter and request for status
are ignored, therefore set to 81h (129) to
9Fh (159) normally.
Set the communication speed of RS485
communication.
2
0: 2400 bps
1: 4800 bps
2: 9600 bps
Set the communication standard of RS485
communication.
0: 8 bits, no parity, stop bit 1
1: 8 bits, no parity, stop bit 2
2: 8 bits, odd number parity, stop bit 1
3: 8 bits, odd number parity, stop bit 2
4: 8 bits, even number parity, stop bit 1
4
5: 8 bits, even number parity, stop bit 2
6: 7 bits, no parity, stop bit 1
7: 7 bits, no parity, stop bit 2
8: 7 bits, odd number parity, stop bit 1
9: 7 bits, odd number parity, stop bit 2
10: 7 bits, even number parity, stop bit 1
11: 7 bits, even number parity, stop bit 2
Communication response time is the short-
est time for setting transmission mode in
RS485 bus for response after the amplifier
10
has received communication data. Actual
data response time depends on the type
and data of order.
Unit [ms]
Set the retry times of RS485 communica-
tion.
9
0 to 8: Number of retrials
9: No retrial
- 70 -
Range of
Address Pr No. Parameter name
setting
8065h
65
Protocol timeout 1 to 255
Change of parameters above is made effective when power is turned on.
• Time required for data transmission per byte is calculated by the following formula for
example in the case of 9600 [bps], 8 bits, parity present (even number or odd number),
and stop bit 1:
(1000/9600) × (1 + 8 + 1 + 1) = 1.14 [ms/byte]
Time is 4.58 [ms/byte] for 2400 [bps], and 2.29 [ms/byte] for 4800 [bps].
Note, however, actual communication time will be added time necessary for processing
received command, and necessary for switching between a line and transmission/
reception control.
2) Extension parameter (special command): 8103h to 81B0h
These are parameters to get motor status or to give commands to the amplifier.
Refer to P.81 "Communication command" for detail.
Default
Function/Description
Protocol timeout is the time allowed from
reception of a character code to reception
of the next one in communication. If normal
character code is not received within this
time, communication is timed out, and
2
received data is discarded. If timeout should
continue to occur, and the number of detec-
tions exceed the retry times, the amplifier
trips due to RS485 communication error.
Unit [seconds]
- 71 -