■ Scan operation
q Push [V/M] to select the Memory mode or the VFO mode,
if necessary.
• "
" appears when in the Memory mode.
w Make sure the squelch level is set to the threshold point.
• Set the squelch level (01 to 25) where the noise is just muted.
e Push [SCAN] to start the scan.
• To change the scan direction, turn [DIAL].
• "SCAN (or P SCAN)" flashes while scanning.
r Push [SCAN] again to stop the scan.
NOTE: Normal scan or Priority scan is pre-programmed
by cloning. Please ask your dealer or system operator for
details.
ï NORMAL SCAN
• Memory lock scan
Repeatedly scans memory
channels except skip (lockout)
channels.
Mch 1
Mch 2*
SKIP
Mch 3
Mch 99
*: Lockout ch
250 msec.
SCAN OPERATION
• VFO scan
R e p e a t e d l y s c a n s a l l
frequencies over the entire
band. Scan step is minimum
channel spacing. (e.g. 25 kHz or
8.33 kHz)
ï PRIORITY SCAN
• Priority memory scan
While scanning in the Memory
mode, priority watch checks for
a s i g n a l o n t h e s e l e c t e d
prior ity channel ever y 250
msec. and skips the lockout
channel(s).
3
lowest
highest
Start
frequency
frequency
Scan
Jump
250 msec.
250 msec.
Mch 1
Mch 2*
SKIP
Priority
ch
Mch 3
Mch 99
*: Lockout ch
6
Need help?
Do you have a question about the IC-A110EURO and is the answer not in the manual?