<Selection method of advanced magnetic flux vector control>
Perform secure wiring. (Refer to page 8.)
Set the motor. (Pr. 71) (Refer to page 54.)
Mitsubishi standard
motor
Mitsubishi high
efficiency motor
Mitsubishi constant-
torque motor
Other
manufacturer's
standard motor
Other
manufacturer's
constant torque
motor
*1
For other settings of Pr. 71 , refer to section 4 of
*2
Refer to page 62 for offline auto tuning.
Set the motor capacity and the number of motor poles according as required.
(Pr. 80, Pr. 81) (Refer to page 54.)
Set the run command. (Refer to page 73.)
As required
· Perform offline auto tuning. (Pr.96) (refer to page 62).
· Select online auto tuning. (Pr.95) (refer to page
REMARKS
· When higher accuracy operation is necessary, set online auto tuning after performing offline auto tuning and select real
sensorless vector control.
· Use Pr. 89 to adjust the motor speed fluctuation at load fluctuation. (Refer to section 4 of
Motor
SF-JR
SF-JR 4P-1.5kW or less
SF-HR
Others
SF-JRCA 200V 4P
SF-HRCA 200V 4P
Others (SF-JRC, etc.)
Instruction Manual (applied).
Set the motor capacity (kW) in Pr. 80 Motor capacity and set the number
of motor poles (number of poles) in Pr. 81 Number of motor poles. (V/F
control is performed when the setting is "9999" (initial value).
Select the start command and speed command.
(1) Start command
1) Operation panel: Setting by pressing
operation panel
2) External command: Setting by forward rotation or reverse
rotation command (terminal STF or STR)
(2)Speed command
1) Operation panel: Setting by pressing
2) External analog command (terminal 2 or 4) :
Give a speed command using the analog signal input to
terminal 2 (or terminal 4).
3) Multi-speed command:
The external signals (RH, RM, RL) may also be used to give
speed command.

Test run

).
66
Pr. 71 Setting
*1
0 (initial value)
20
40
Offline auto tuning is
3
necessary.
1
50
Offline auto tuning is
13
necessary.
Offline auto tuning is
3
necessary.
Offline auto tuning is
13
necessary.
Instruction Manual (applied).)
Before operation
Remarks
*2
*2
*2
*2
/
of the
of the operation panel
55
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents