Mitsubishi Electric FR-A700 Instruction Manual page 100

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Parameter
Name
DU/PU main display
52
data selection
FM terminal
54
function selection
AM terminal
158
function selection
Watt-hour meter
170
clear
Operation hour
171
meter clear
Monitor decimal
268
digits selection
Energization time
563
carrying-over times
Operating time
564
carrying-over times
AM output filter
867
Cumulative power
monitor digit shifted
891
times
Incre
Initial
Range
ments
Value
0, 5 to 14,
Select monitor to be displayed on the
operation panel and parameter unit and
17 to 20,
monitor to be output to the terminal FM and
1
0
22 to 25,
AM.
32 to 35,
0 : Output frequency (Pr. 52)
50 to 57,100
1 : Output frequency (Pr. 54, Pr. 158)
1 to 3, 5 to
2 : Output current (Pr. 54, Pr. 158)
3 : Output voltage (Pr. 54, Pr. 158)
14, 17, 18,
5 : Frequency setting
1
1
21, 24,
6 : Running speed
32 to 34,
7 : Motor torque
50, 52, 53
8 : Converter output voltage
9 : Regenerative brake duty
10 : Electronic thermal relay function load
11 : Output current peak value
12 : Converter output voltage peak value
13 : Input power
14 : Output power
17 : Load meter
18 : Motor excitation current
19 : Position pulse* (Pr. 52)
20 : Cumulative energization time (Pr. 52)
21 : Reference voltage output (Pr. 54, Pr. 158)
22 : Orientation status* (Pr. 52)
23 : Actual operation time (Pr. 52)
1 to 3, 5 to
24 : Motor load factor
14, 17, 18,
25 : Cumulative power (Pr. 52)
1
1
21, 24, 32 to
32 : Torque command
33 : Torque current command
34, 50, 52,
34 : Motor output
53
35 : Feedback pulse* (Pr. 52)
50 : Power saving effect
51 : Cumulative saving power (Pr. 52)
52 : PID set point
53 : PID measured value
54 : PID deviation (Pr. 52)
55 : Input/output terminal status (Pr. 52)
56 : Option input terminal status (Pr. 52)
57 : Option output terminal status (Pr. 52)
100 : Set frequency is displayed during a
* Available only when the FR-A7AP is
0
Set "0" to clear the watt-hour meter monitor.
Set the maximum value when monitoring
10
1
9999
from communication to 0 to 9999kWh.
Set the maximum value when monitoring
9999
from communication to 0 to 65535kWh.
Set "0" in the parameter to clear the watt-
1
9999
0, 9999
hour monitor.
Setting "9999" has no effect.
0
Displays the monitor as integral value.
1
9999
1
Displays the monitor in increments of 0.1.
9999
No fixed decimal position
The numbers of cumulative energization time
(0 to
1
0
monitor exceeded 65535h is displayed.
65535)
Reading only
The numbers of operation time monitor
(0 to
1
0
exceeded 65535h is displayed.
65535)
Reading only
0.01s
0.01s
0 to 5s
Set the output filter of terminal AM.
Set the number of times to shift the
0 to 4
cumulative power monitor digit.
Clamp the monitor value at maximum.
1
9999
No shift
9999
Clear the monitor value when it exceeds
the maximum value.
Description
factor
stop and output frequency is displayed
during operation (Pr. 52)
mounted.
Parameter List
All
Para
Param
param
meter
eter
eter
copy
clear
clear
: enabled
× : disabled
×
×
×
×
3
×
×
×
×
×
×
95