Peripheral devices
400V class
Motor Output
Applicable Inverter Type
(kW)
*1
0.4
FR-A740-0.4K
0.75
FR-A740-0.75K
1.5
FR-A740-1.5K
2.2
FR-A740-2.2K
3.7
FR-A740-3.7K
5.5
FR-A740-5.5K
7.5
FR-A740-7.5K
11
FR-A740-11K
15
FR-A740-15K
18.5
FR-A740-18.5K
22
FR-A740-22K
30
FR-A740-30K
37
FR-A740-37K
45
FR-A740-45K
55
FR-A740-55K
75
FR-A740-75K
90
FR-A740-90K
110
FR-A740-110K
132
FR-A740-132K
160
FR-A740-160K
185
FR-A740-185K
220
FR-A740-220K
250
FR-A740-250K
280
FR-A740-280K
315
FR-A740-315K
355
FR-A740-355K
400
FR-A740-400K
450
FR-A740-450K
500
FR-A740-500K
*1
Selections for use of the Mitsubishi 4-pole standard motor with power supply voltage of 400VAC 50Hz.
*2
Select the MCCB according to the inverter power supply capacity.
Install one MCCB per inverter.
For installations in the United States or Canada, use the fuse certified by the UL and cUL.
(Refer to page 181.)
*3
Magnetic contactor is selected based on the AC-1 class. The electrical durability of magnetic contactor is 500,000 times. When the magnetic
contactor is used for emergency stop during motor driving, the electrical durability is 25 times.
When using the MC for emergency stop during motor driving or using on the motor side during commercial-power supply operation, select the MC
with class AC-3 rated current for the motor rated current.
*4
When the breaker on the inverter primary side trips, check for the wiring fault (short circuit), damage to internal parts of the inverter, etc. Identify
the cause of the trip, then remove the cause and power on the breaker.
4
Breaker Selection
Reactor connection
without
30AF 5A
30AF 5A
30AF 5A
30AF 5A
30AF 10A
30AF 10A
30AF 10A
30AF 10A
30AF 20A
30AF 15A
30AF 30A
30AF 20A
30AF 30A
30AF 30A
50AF 50A
50AF 40A
100AF 60A
50AF 50A
100AF 75A
100AF 60A
100AF 100A
100AF 75A
225AF 125A
100AF 100A
225AF 150A
225AF 125A
225AF 175A
225AF 150A
225AF 200A
225AF 175A
225AF 225A
225AF 225A
225AF 225A
400AF 400A
400AF 400A
400AF 400A
600AF 500A
600AF 600A
600AF 600A
800AF 700A
800AF 800A
1000AF 900A
1000AF 1000A
1200AF 1200A
Input Side Magnetic Contactor
*2,4
Reactor connection
with
without
S-N10
S-N10
S-N10
S-N10
S-N10
S-N20
S-N20
S-N20
S-N25
S-N25
S-N35
S-N50
S-N65
S-N80
S-N80
*3
with
S-N10
S-N10
S-N10
S-N10
S-N10
S-N11, N12
S-N20
S-N20
S-N20
S-N25
S-N25
S-N50
S-N50
S-N65
S-N80
S-N95
S-N150
S-N180
S-N220
S-N300
S-N300
S-N400
S-N600
S-N600
S-N600
S-N600
S-N800
1000A
Rated product
1000A
Rated product
MCCB
INV
IM
MCCB
INV
IM