Dedicated motor (SF-V5RU(H)) outline dimension drawings (flange type)
Frame Number 90L
SF-V5RUF(H)
1K
Connector (for encoder)
MS3102A20-29P
LL
KB
LG
Exhaust
Section
AA
Suction
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Frame Number 160M, 160L, 180M, 180L
SF-V5RUF(H)
11K
,
15K
,
18K
Connector (for encoder)
MS3102A20-29P
LL
KB
LG
Exhaust
Section
AA
Suction
Direction of
Earth (ground) terminal (M8)
cooling fan wind
Mark for earthing (grounding)
With guard wires
Dimensions table
SF-V5RU
SF-V5RU
SF-V5RU
SF-V5RU
Flange
Frame
K
K1
K3
K4
Number
No.
1
FF165
90L
2
1
FF215 100L
3
2
1
FF215 112M
5
3
2
FF265 132S
7
5
3
1
FF265 132M
11
7
5
2
FF300 160M
15
11
7
3
FF300 160L
18
FF350 180M
22
15
11
18
15
5
FF350 180L
30
7
FF400 200L
37, 45
22, 30
18, 22
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
For use under the shaft, the protection structure of the cooling fan is IP20.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3 The size difference of top and bottom of the shaft center height is
4 The 400V class motor has -H at the end of its type name.
LR
KL
Q
LE
LN LZ
QK
A
B
B
A
W
S
For cooling fan (A, B)
Section BB
For motor (U, V, W)
For thermal protector (G1, G2)
A
B
U
V
W
G1
G2
Earthing (grounding)
terminal (M4)
,
22K
LR
Q
LE
LN LZ
KL
QK
A
B
B
A
W
S
Section BB
For cooling fan (A, B, C)
Mass
(kg)
D
IE
KB
KD
KL
LA
26.5
183.6
198.5
27
220
165
37
207
130
213
27
231
215
46
228
141
239
27
242
215
65
266
156
256
27
256
265
70
266
156
294
27
256
265
110
318
207
318
56
330
300
125
318
207
362
56
330
300
160
363
230 378.5
56
352
350
185
225
363
230 416.5
56
352
350
270
406
255
485
90
346
400
290
0
-0.5
Outline dimension drawings
Frame Number 100L, 112M, 132S, 132M
SF-V5RUF(H)
2K
,
3K
,
Connector (for encoder)
MS3102A20-29P
LL
KB
Exhaust
Section
Suction
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Frame Number 200L
SF-V5RUF(H)
30K
,
37K
Connector (for encoder)
MS3102A20-29P
LL
KB
Exhaust
Suction
Direction of
Earth (ground) terminal (M12)
cooling fan wind
Mark for earthing (grounding)
With guard wires
For motor (U, V, W)
Earthing (grounding)
terminal (M8)
Make sure to earth the earth terminal of the flange section
For thermal protector (G1, G2)
as well as the earth terminal in the terminal box.
Motor
LB
LC
LE
LG
LL
LN
LZ
LR
130j6
200
3.5
12
402
4
12
50
180j6
250
4
16
432
4
14.5
60
180j6
250
4
16
448
4
14.5
60
230j6
300
4
20
484
4
14.5
80
230j6
300
4
20
522
4
14.5
80
250j6
350
5
20
625
4
18.5
110
250j6
350
5
20
669
4
18.5
110
300j6
400
5
20
690
4
18.5
110
300j6
400
5
20
728
4
18.5
110
350j6
450
5
22
823.5
8
18.5
140
5K
,
7K
LR
Q
LG
LE
KL
QK
AA
A
B
B
W
S
Section BB
,
45K
LR
Q
QK
KL
LG
LE
Section
AA
B
A
B
KD
A
W
S
Section BB
Shaft End
Terminal Screw Size
Q
QK
S
T
U
W
U,V,W A,B,(C) G1,G2
50
40
24j6
7
4
8
M6
60
45
28j6
7
4
8
M6
60
45
28j6
7
4
8
M6
80
63
38k6
8
5
10
M6
80
63
38k6
8
5
10
M6
110
90
42k6
8
5
12
M8
110
90
42k6
8
5
12
M8
110
90
48k6
9
5.5
14
M8
110
90
55m6
10
6
16
M8
140
110
60m6
11
7
18
M10
LN LZ
A
LN LZ
(Unit: mm)
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
6
173

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents