Mitsubishi Electric FR-A700 Instruction Manual page 164

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

400V class
Type FR-A740-
K
Applicable motor capacity (kW)
*1
Rated capacity (kVA)
*2
Rated current (A)
Overload current rating
*5
Voltage
*6
Regenerative
Maximum value/
braking torque
permissible duty
Rated input
AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply capacity (kVA)
*7
Protective structure
*9
Cooling system
Approx. mass (kg)
Type FR-A740-
K
Applicable motor capacity (kW)
*1
Rated capacity (kVA)
*2
Rated current (A)
*3
Overload current rating
*4
Voltage
*5
Regenerative
Maximum value/
braking torque
permissible duty
Rated input
AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply capacity (kVA)
*7
Protective structure (JEM 1030)
Cooling system
Approx. mass (kg)
*1. The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
*2. The rated output capacity indicated assumes that the output voltage is 440V.
*3. When operating the inverter of 75K or more with a value larger than 2kHz set in Pr. 72 PWM frequency selection, the rated output current is the value in
parenthesis.
*4. The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for
the inverter and motor to return to or below the temperatures under 100% load.
*5. The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However,
the pulse voltage value of the inverter output side voltage remains unchanged at about
*6. With the dedicated external brake resistor FR-ABR-H (option), the 0.4K to 7.5K and 11K to 22K will achieve the performance of 100% torque/10%ED and
100% torque/6%ED respectively.
*7. The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).
*8. When the hook of the inverter front cover is cut off for installation of the plug-in option, the inverter changes to an open type (IP00).
*9. FR-DU07:IP40 (except for the PU connector)
0.4
0.75
1.5
2.2
0.4
0.75
1.5
2.2
1.1
1.9
3
4.6
1.5
2.5
4
6
150% 60s, 200% 3s (inverse time characteristics) ambient temperature 50°C
100% torque/2%ED
1.5
2.5
4.5
5.5
Enclosed type (IP20)
Self-cooling
3.8
3.8
3.8
3.8
75
90
110
132
75
90
110
132
110
137
165
198
144
180
216
260
(122)
(153)
(184)
(221)
150% 60s, 200% 3s (inverse time characteristics) ambient temperature 50°C
110
137
165
198
*9
50
57
72
72
3.7
5.5
7.5
11
15
3.7
5.5
7.5
11
15
6.9
9.1
13
17.5
23.6
9
12
17
23
31
Three-phase 380 to 480V
20% torque/continuous
*6
Three-phase 380 to 480V 50Hz/60Hz
323 to 528V 50Hz/60Hz
±
5%
9
12
17
20
28
*9
Forced air cooling
3.8
7.1
7.1
7.5
7.5
160
185
220
250
280
160
185
220
250
280
248
275
329
367
417
325
361
432
481
547
(276)
(307)
(367)
(409)
(465)
Three-phase 380 to 480V
10% torque/continuous
Three-phase 380 to 480V 50Hz/60Hz
323 to 528V 50Hz/60H
±
5%
248
275
329
367
417
Open type (IP00)
Forced air cooling
110
110
175
175
175
that of the power supply.
2
Rating
18.5
22
30
37
45
18.5
22
30
37
45
29
32.8
43.4
54
65
38
44
57
71
86
20% torque/continuous
*6
34
41
52
66
80
Open type (IP00)
13
13
23
35
35
315
355
400
450
500
315
355
400
450
500
465
521
587
660
733
610
683
770
866
962
(519)
(581)
(655)
(736)
(818)
465
521
587
660
733
260
260
370
370
370
55
55
84
110
100
37
6
159