Mitsubishi Electric FR-A700 Instruction Manual page 115

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Parameter List
Parameter
RUN terminal
190
function selection
SU terminal
191
function selection
IPF terminal
192
function selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal
195
function selection
ABC2 terminal
196
function selection
232 to 239
Refer to Pr. 4 to Pr. 6.
240
Refer to Pr. 72.
241
Refer to Pr. 125 and Pr. 126.
242, 243
Refer to Pr. 73.
110
Incre
Initial
Name
ments
Value
1
0
1
1
1
2
1
3
1
4
1
99
1
9999
Range
Description
0, 100: Inverter running
1, 101: Up to frequency
0 to 8,
2, 102: Instantaneous power failure/
10 to 20,
undervoltage
25 to 28,
3, 103: Overload alarm
30 to 36, 39,
4, 104: Output frequency detection
41 to 47,
5, 105: Second output frequency detection
64, 70, 84,
6, 106: Third output frequency detection
85, 90 to 99,
7, 107: Regenerative brake pre-alarm
100 to 108,
8, 108: Electronic thermal relay function
pre-alarm
110 to 116,
10, 110:PU operation mode
120,
11, 111: Inverter operation ready
125 to 128,
12, 112:Output current detection
130 to 136,
13, 113:Zero current detection
139,
14, 114:PID lower limit
141 to 147,
15, 115:PID upper limit
164, 170,
16, 116:PID forward/reverse rotation
190 to 199,
output
9999
17, —: Electronic bypass MC1
18, —: Electronic bypass MC2
19, —: Electronic bypass MC3
20, 120:Brake opening request
25, 125:Fan fault output
26, 126:Heatsink overheat pre-alarm
27, 127:Orientation in-position *
28, 128:Orientation error *
30, 130:Forward rotation output *
31, 131:Reverse rotation output *
32, 132:Regenerative status output *
33, 133:Operation ready 2
34, 134:Low speed output
35, 135:Torque detection
36, 136:In-position *
0 to 8,
39, 139:Start time tuning completion
10 to 20,
41, 141:Speed detection
25 to 28,
42, 142:Second speed detection
30 to 36, 39,
43, 143:Third speed detection
41 to 47, 64,
44, 144:Inverter running 2
70, 84, 85,
45, 145:Inverter running and start command
90, 91,
is on
94 to 99,
46, 146:During deceleration at occurrence
100 to 108,
of power failure (retained until
110 to 116,
release)
120,
47, 147:During PID control activated
125 to 128,
64, 164:During retry
130 to 136,
70, 170:PID output interruption
139,
84, 184:PreparatDC current feedingion
141 to 147,
ready signal *
164, 170,
85, 185:DC current feeding
190, 191,
90, 190:Life alarm
194 to 199,
91, 191:Alarm output 3 (power-off signal)
92, 192:Energy saving average value
9999
updated timing
93, 193:Current average monitor signal
94, 194:Alarm output 2
95, 195:Maintenance timer signal
96, 196:Remote output
97, 197:Minor fault output 2
98, 198:Minor fault output
99, 199:Alarm output
9999: No function
0 to 99: Positive logic
100 to 199: Negative logic
* Available only when used with the FR-A7AP.
All
Para
Param
param
meter
eter
eter
copy
clear
clear
: enabled
× : disabled
×
×
×
×
×
×
×