COMPONENT ACCESS AND SERVICE PROCEDURES
To remove and replace the power generator
boards begin by removing the heat sink thermal
cut out. Next remove the two metal clips that
clamp the heat sinks together (if present). Gently
pry the clip off with a small screwdriver. (Fig. 25)
To unplug the fl at cable connector on the fi lter
board and the power generator board (Fig. 25A)
use the special cable removal tool.
Flat Cable
Connector
Fig. 25A
Grip the connector with the tool as shown in the
photo and pull up to release the connector (Fig
25B).
Unplug the Blue and Black wires from the power
generator board terminals X1 & X2. When
reconnecting these wires terminal polarity is not
important. Remove the two torx screws that mount
the board to the outer case. (Fig. 25C).
Lift out the induction power generator board. (Fig.
25D)
Fig. 25D

Replacing The Induction Generator Power Board

Page 25
The tool is packaged with
each power board and fi lter
board as well as with the
replacement cable.
Pull Up On
Tool
Fig. 25B
Fig. 25
Cable Removal
Tool
Torx
Screw
Black &
Blue wires
Torx
Screw
Fig. 25C