ELECTROLUX ICON 36" Induction Cooktop Error Codes
Error
Possible Cause or Condition
70
See error 30
71
Internal generator error, sync
(center cooking zone)
72
See error 32
73
See error 33
74
Internal generator error, communication
(3 zones induction module)
75
See error 35
76
Communication Error in the 3 cook zones
induction module for the center cooking
zones.
77
Heat sink temperature sensor break in the
3 cook zones induction module for the
center cooking zones.
80
Flash/Rom check fail (EEPROM data)
90
AC input voltage too high in the 2 cook
zones induction module.
91
Internal generator error, sync in the 2 cook
zones induction module.
92
12V on the service section too low in the 2
cook zones induction module.
93
5V overcurrent on the switched 5V on the
service section (2 zones induction module).
94
Internal generator error, communication in
the 2 cook zones induction module.
95
AC input voltage too low in the 2 cook
zones induction module.
96
Communication Error in the 2 cook zones
induction module.
97
Heat sink temperature sensor break in the
2 cook zones induction module.
NOTE: If multiple changing error codes are displayed check for disconnected wires or cables.
Suggested Corrective Action
See error 30
- Test cables & connections on center generator circuit board
(single).
- Replace the generator circuit board (single) in the 3 zones
induction module .
See error 32
See error 33
- Check cable between fi lter board X13 and generator board X10
- Replace the fi lter circuit board in the 3 zones induction module
- Replace generator circuit board in the 3 zones induction module
See error 35
- Verify all communication cables between user interface and
both induction generator modules.
- Replace the fi lter circuit board in the 3 zones induction module .
- Replace generator circuit board for the center cook zone in the
3 zones induction module
- Replace generator circuit board for the center cook zone in the
3 zones induction module
- Replace main power touch control
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Replace the fi lter board in the 2 zones induction module
- Test cables & connections on right generator circuit board.
- Replace the right side generator circuit board
- Test all cables & connections on fi lter circuit board in the 2
zones induction module.
- Replace the fi lter circuit board in the 2 zones induction module .
- Replace generator circuit boards in the 2 zones induction
module
- Verify cable between fi lter board X58 and generator board X10
on the 2 zones induction module.
- Verify the heat sink thermal cutout in the 2 zones induction
module is connected and resistance is approximately 0 ohms.
- Replace the fi lter circuit board in the 2 zones induction module.
- Replace generator circuit board in the 2 zones induction
module
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Verify the fuse resistance is approximatively 0 ohms in the 2
zones induction module.
- Replace the fi lter circuit board in the 2 zones induction module
- Verify all communication cables between user interface and
both induction generator module.
- Replace the fi lter circuit board in the 2 zones induction module .
- Replace generator circuit board in the 2 zones induction module
- Replace the generator circuit board in the 2 zones induction
module
Page 31