Important Safety - Electrolux E36IC75FSS Service Manual

Icon designer series 36” induction drop-in cooktop
Hide thumbs Also See for E36IC75FSS:
Table of Contents

Advertisement

INDUCTION COOKTOP INSTALLATION INSTRUCTIONS
Important Notes to the Installer
1. Read all instructions contained in these installation
instructions before installing the cooktop.
2. Remove all packing material before connecting the
electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
5. Only certain cooktop models may be installed over
certain built-in electric oven models. Approved
cooktops and built-in ovens are listed by the MFG ID
number and product code. (Refer to the Information
Sheet for the model numbers).
Important Note to the Consumer
Keep these instructions with your Use and Care Guide for
future reference.

IMPORTANT SAFETY

INSTRUCTIONS
• Be sure your cooktop is installed and grounded
properly by a qualified installer or service
technician.
• This cooktop must be electrically grounded in
accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA No.
70—latest edition in the United States.
The electrical power to the cooktop
WARNING
must be shut off while line connections are being
made. Failure to do so could result in serious injury
or death.
Provide Electrical Connection
Install the junction box under the cabinet and run 120/
240 or 120/208 Volt, AC wire from the main circuit
panel. NOTE: DO NOT connect the wire to the circuit
panel at this time.
Electrical Requirements
Observe all governing codes and local ordinances.
1. A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on a
separate circuit fused on both sides of the line (time-
delay fuse or circuit breaker is recommended). DO
NOT fuse neutral. The fuse size must not exceed the
circuit rating of the appliance specified on the
nameplate.
2. A circuit breaker or fuse rated at 50 Amp is
recommended for this appliance.
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with the National Electrical Code ANSI/NFPA No. 70–
latest edition and local codes and ordinances.
An extension cord must not be used
WARNING
with this appliance. Such use may result in a fire,
electrical shock, or other personal injury.
3. The appliance should be connected to the fused
disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed cable. The flexible
armored cable extending from this appliance should
be connected directly to the grounded junction box.
The junction box should be located as shown in
Figure 2 with as much slack as possible remaining in
the cable between the box and the appliance, so it
can be moved if servicing is ever necessary.
4. A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
Unpacking Instructions
1. Unpack and visually inspect the cooktop.
2. Be sure the bottle of cleaner conditioner packed in the
literature bag is left where the user can find it easily. It
is important that the ceramic-glass cooktop be
pretreated before use. See Cooktop Cleaning and
Maintenance section in the Use and Care Guide.
Electrical Connection
Connect the flexible armored cable that extends from
the surface unit to the junction box using a suitable
strain relief at the point the armored cable enters the
junction box. Then make the electrical connection as
follows.
Electrical ground is required on this appliance.
This appliance is equipped with a
copper conductor flexible cable. If connection is
made to aluminum house wiring, use only special
connectors which are approved for joining copper
and aluminum wires in accordance with the
National Electrical Code and local codes and
ordinances. Improper connection of aluminum
house wiring to copper leads can result in a short
circuit or fire. Follow the connector manufacturer
recommended procedure closely.
This appliance is manufactured with a supply wire and a
frame connected green or bare copper grounding wire.
Page 10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents