Gree GWH09MA-K3NNA3F Service Manual page 72

Refrigerant r410a
Table of Contents

Advertisement

Removal Procedure
Remove magnetic coil
Remove the screw of the magnetic
coil. Remove the magnetic coil.
Remove the gas valve and liquid valve
Solder off the capillary, the valve and
condensate outlet pipe. Do not block the
capillary when replacing it. Loosen the 2
screws fixing the gas valve. Solder off the
gas valve and return air duct. (note: when
soldering off the gas valve, wrap it with wet
cloth
to
avoid
temperature.) Loosen the 2 screws fixing
the liquid valve. Solder off the liquid valve.
Remove compressor
Discharge the refrigerant. Solder off
a
the pipe connecting the compressor
(including 4-way valve, compressor,
condenser, capillary.) Do not block
the capillary during soldering.
b
Loosen the ground bolts fixing the
compressor.
compressor.
damage
by
high
Then
remove
the
magnetic coil
4-way valve
liquid valve
gas valve
capillary
compressor
69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents