Installation Manual
Safety Requirements For Electric Appliances
1. A dedicated power supply circuit should be used in accordance with local electrical safety regulations.
2. Don't drag the power cord emphatically.
3.The unit should be reliably earthed and connected to the special earth device by the professionals.
The air switch must have the functions of magnetic tripping and heat tripping to prevent short circuit and overloading.
4.The min. distance between the unit and combustive surface is 1.5m.
5.The appliance shall be installed in accordance with national wiring regulations.
6.An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed
wiring.
NOTE:
Make sure the live wire ,neutral wire and earth wire in the family power socket are properlly connected.
There should be reliable circuit in the diagram.
Inadequate or incorrect electrical connections may cause electrocution or fire.
Earthing requirements
1.Air conditioner is type I electric appliance. Please ensure the the unit is reliably earthed.
2. The yellow-green two-color wire in air conditioner is the earthing wire which can not be used for other proposes. Improper
earthing may cause electrocution.
3. The earth resistance should accord to the National Criterion.
4. The user's power must have reliable earthing terminal. Please don't connect the earthing wire with the following :
Tap water pipe
Other places that professional personnel consider is unreliable
5. The model and rating values for fuses accord with the silk print on fuse cover or related PCB board.
Gas pipe
Contamination pipe
29