Omron E4C-UDA Instruction Manual page 14

Ultrasonic sensor with separated digital amplifier
Table of Contents

Advertisement

Setting procedure
SET
RUN
Switch the SET/RUN switch
to RUN.
This completes setting, and the display returns
to regular measurement.
3) Direct setting
Directly set the distance with respect to output (1 V, 5 V).
Setting procedure
SET
RUN
Switch the SET/RUN switch
to RUN.
This completes setting, and the display
returns to regular measurement.
Note: When the values of the first and second points are the same, "NEAR" flashes twice on the error display, and the points
must be set again.
Main display:
Sub-display:
The display moves to the next setting.
Main display:
Sub-display:
The display moves to the next setting.
Select [10AR] by the MODE key,
and then press the UP or DOWN key to select [RFCT].
Press the MODE key to apply the setting. The current
distance is displayed on the sub-display.
Align with the rear, and hold down the MODE key for
more than 3 seconds.
"OK" is displayed on the sub-display to indicate that
the setting is completed.
Press the MODE key.
Output voltage
(V)
5
1
0
50
300
Select [10AR] by the MODE key,
and then press the UP or DOWN key to select [MFCS].
The distance value currently assigned to 1 V is displayed.
Press the UP or DOWN key to set the distance to assign to 1 V,
and press the MODE key to apply the setting.
The distance value currently assigned to 5 V is displayed.
Press the UP or DOWN key to set the distance to assign to 5 V,
and press the MODE key to apply the setting.
"OK" is displayed on the sub-display to indicate that the setting
is completed.
Press the MODE key.
- 14 -
Output voltage
(V)
5
1
Measured
0
100 200
value (mm)
Measured
value (mm)