Setting the output range (analog output model)
Function
• This function sets the range and display ratio of linear output with respect to the display value.
• This function is mounted only on the analog output model.
Note: The preset output range is canceled by initializing the product settings.
Note: When the output range is set, zero reset and offset are automatically cleared.
1) 2-point setting
• Determine the 1 V and 5 V ranges at the workpiece position.
• The output ramp is as follows according to the positional
relationship between the first and second points.
Setting procedure
SET
RUN
Switch the SET/RUN switch
to RUN.
This completes setting, and the display
returns to regular measurement.
Note: When the values of the first and second points are the same, "NEAR" flashes twice on the error display, and the points
must be set again.
2) Background setting
Set the analog output referenced to the background distance (5
V).
Main display:
Sub-display:
The display moves to the next setting.
5 V
First point
< second point
1 V
5 V
First point
> second point
1 V
Select [10AR] by the MODE key,
and then press the UP or DOWN key to select [2PNT].
Press the MODE key to apply the setting.
The current distance is displayed on the sub-display.
Press the MODE key for 1 second or more to apply the setting.
Place the workpiece at the second point.
"B 5V" is displayed on the main display,
and the current distance is displayed on the sub-display.
Press the MODE key for 1 second or more to apply the setting.
"OK" is displayed on the sub-display to indicate that the setting
is completed.
Press the MODE key.
5 V
1 V
Nearest point
- 13 -
Second point
First point
Second point
First point
Distance to rear