ABUZ n,m
ASCR n,m
AMSG n,m
AHLD n,m
AREC n,m
AMON n,m
Other Commands
MCLK n
LANG n
42
Alarm buzzer on/off
n : 0 = External alarm, 1 = Manual alarm, 2 = Vloss alarm,
3 = Motion alarm
m : 0 = off, 1 = on
Alarm screen on/off
n : 0 = External alarm, 1 = Manual alarm, 2 = Vloss alarm,
3 = Motion alarm
m : 0 = off, 1 = on
Alarm message latch on/off
n : 0 = External alarm, 1 = Manual alarm, 2 = Vloss alarm,
3 = Motion alarm
m : 0 = off, 1 = on
Alarm hold time set
n : 0 = External alarm, 1 = Manual alarm, 2 = Vloss alarm,
3 = Motion alarm
m : Alarm hold time (1~99)
Alarm recording set
n : 0 = External alarm, 1 = Manual alarm, 2 = Vloss alarm,
m : 0 = INT, 1 = ONLY, 2 = UNC
Alarm spot monitor set
n : 0 = External alarm, 1 = Manual alarm, 2 = Vloss alarm,
3 = Motion alarm
m : First bit = 1, Second bit = 2, Third bit = 3, Fourth bit = 4
(0x00 ~0x0f) Bit = 0 : Spot monitor off
Bit = 1 : Spot monitor on
Menu lock and user change lock
n : 0 = Setup menu lock off, User change lock off
1 = Setup menu lock on, User change lock off
2 = Setup menu lock off, User change lock on
3 = Setup menu lock on, User change lock on
Language set
n : 0 = English, 1 = German, 2 = French, 3 = Italian, 4 = Spanish