Mouse Setup: The sensitivity of the mouse operation can be changed using the Mouse
Setup option. The range is: MIN (-009) to MAX (+009).
Master / Slave: When installed as part of a network, this setting determines whether the
unit is a master or slave unit in the network.
Network Type: The multiplexer can be set to RS-232, RS-422, or RS-485 when
connected to a network.
Baud Rate: When connected to a network, the baud rate can be set to 1200, 2400,
4800, 9600, or 19200.
Unit Address: Networked multiplexers can be assigned addresses from 001 to 255.
Protocol: To use the multiplexer protocol, set to option A. To use a camera controller
protocol, set to option B1.
Password Setup
The Password Setup screen allows the user to assign PIN codes to the Administrator and
up to four users. Keep a copy of the Administrator password in a safe place. Once you
have changed the ADMIN password from the default setting, you will not be able to access
protected areas without it.
An Administrator password is required to access the Setup Menu. After changing the
passwords, keep it in a safe place. The new passwords will be the only way to access
certain features of the multiplexer once you have changed from the factory default
passwords.
NOTE: The factory default passwords are listed in the Technical Specifications section at
the back of this manual.
Setup Menu Password: When set to ON, only the Administrator can access the Setup
menu and make changes.
The Admin Password screen shown below appears. Enter the password by moving the
cursor over the desired number and pressing the ACCEPT key. As you enter each digit,
the circles fill in and the cursor moves to the right one position. Once you have entered
all four digits, select OK. If you have entered an incorrect number, an Incorrect
Password message displays for ten seconds, then the unit returns to a live display.
Repeat the process and re-enter the correct Admin Password.
32
Need help?
Do you have a question about the 4, 9, &16-ChannelTalon Triplex Color Multiplexers and is the answer not in the manual?