Auto
HDCP content protection is applied to the iScan Duo output only if the input
signal is protected
On
HDCP content protection is always applied to the iScan Duo output if the
Duo detects a display with HDCP even if the input signal is unprotected
7. Updated Serial Automation Commands
New commands are added to support CMS and other new features including:
•
CMS commands
— Input and Output Chromaticity controls
— Color Gamut controls
— Gray Scale controls
•
Product Name and Version Number queries
•
Y/C Delay, CUE Correction, Border and Mask Levels
•
Input and Output HDCP modes
•
Input Colorimetry
•
Menu Timeout
•
Menu Navigation
•
More consistent factory default commands
See Updated Serial Automation command document for more details
IMPROVEMENTS
•
Added 1080p30 pre-defined output format.
•
Front Panel displays firmware version when Info Screen – About is selected.
•
Zooming range is increased to 16x the input image size.
•
Improved input switching by reducing flashing and flickering.
•
Improved analog video performance by reducing noise levels.
•
Info Screen provides more timing information.
•
Added Hardware handshaking support for serial automation.
BUG FIXES
•
The new method of applying HDCP on the iScan Duo's output introduced a bug that
caused some displays to not show video.
•
OSD indicator sometimes remained on the screen indefinitely.
•
Gamut settings did not get saved when in Standby.
•
OSD corruption occurred when selecting inputs.
•
RGBS2 input did not work.
•
Wrong Hsync/Vsync Polarity for 480p/576p output formats.