Service Data; Diesel Engine; Fuel And Lubricant Chart - Takeuchi TB125 Operator's Manual

Compact excavator
Table of Contents

Advertisement

MAINTENANCE

Service Data

Fuel and Lubricant Chart

Use different fuels, lubricants and greases according to the temperature, referring to the chart below.
¡ Change the lubricant earlier than as shown in the table if it is extremely dirty or its
performance has deteriorated severely.
¡ Whenever possible, use the same brand of lubricant as before. If changing with a different
brand, replace the entire quantity – do not mix different brands.
Part
Diesel
Engine
engine oil
oil pan
API-CD
Antiwear
hydraulic oil
Hydraulic
(Option:
tank
Biodegrad-
able oil)
Fuel tank
Diesel fuel
Coolant
Engine
(water +
cooling
coolant)**
system
Travel
Gear oil
reduction
API-GL-4
gear
Slew
Lithium
bearing
based
Working
grease
equipment
EP-2
NLGI No. 2
Levers
{ } : Serial No. 14515346 ~
< >: for the tropics Serial No.14517254~
Type by temperature
Type
-22 -4 14 32 50 68 86 104
-30 -20 -10 0 10 20 30 40
SAE 5W-20
Use a clean, Quality fuel for good performance and optimum engine life.
¡ To prevent fuel flow problems in cold weather, use diesel fuel with a pour point of at
least -12°C (10°F) below the lowest expected ambient temperature.
¡ Minimum cetane number is 45. Low temperature or high altitude operation may
require the use of fuel with a higher cetane number.
50% coolant mixture
SAE 10W-30
SAE 15W-40
ISO VG32
ISO VG46
ISO VG68
30% coolant mixture
SAE 90
94
Replacement
°
F
interval
°
C
Upper limit:
TB125:3.6(3.8)
TB135:4.7(5.0)
TB145:7.4(7.8)
After first 50 hrs.
Every 250 hrs.
Lower limit:
TB125:2.4(2.5)
TB135:2.9(3.1)
TB145:4.0(4.2)
System:
TB125:74(78.2)
TB135:85(89.8)
TB145:115(121.5)
Every 2000 hrs.
Tank:
TB125:48(50.7)
TB135:48(50.7)
TB145:74(77.9)
Tank:
TB125:51(53.6)
TB135:51(53.6)
TB145:73(76.6)
TB125:3.5(3.7)
TB135:5.4(5.7)
Every 1000 hrs.
TB145:6.7(7.1)
{TB145:9.6(10.1)}
<TB145:10.6(11.2)>
TB125:0.5(0.53)
After first 100 to
TB135:0.6(0.63)
250 hrs.*
TB145:0.8(0.85)
Every 1000 hrs.
{TB145:1.0(1.06)}
Every 50 hrs.
As
Daily or every
required
10 hrs.
When
required
Capacity
R
(US. qt.)

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Tb145Tb135

Table of Contents