MAINTENANCE

Service Data

Fuel and Lubricant Chart
Use different fuels, lubricants and greases according to the temperature, referring to the
chart below.
¡ Change the lubricant earlier than as shown in the table if it is extremely dirty or its
performance has deteriorated severely.
¡ Whenever possible, use the same brand of lubricant as before. If changing with a different
brand, replace the entire quantity – do not mix different brands.
Part
Diesel
Engine
engine oil
oil pan
API-CD
Antiwear
Hydraulic
hydraulic oil
tank
Fuel tank
Diesel fuel
Engine cool-
Coolant (water **
ing system
+ coolant ***)
Travel reduc-
Gear oil
API-GL-4
tion gear
Slew
Lithium
bearing
based
Working
grease
equipment
EP-2
Levers
NLGI No. 2
*
If the percentage of the traveling time within the total operating time is high, replace the
gear oil earlier than the specified time.
** For water, use tap water (soft). Do not use well or river water.
*** When the ambient temperature drops below 0°C, add coolant (antifreeze). Follow the
coolant manufacturer's instructions to determine the mixture ratio.
Type by temperature
Type
-22 -4 14 32 50 68 86 104
-30 -20 -10 0 10 20 30 40
SAE 5W-20
Use a clean, Quality fuel for good performance and optimum engine life.
¡ To prevent fuel flow problems in cold weather, use diesel fuel with a pour point of
at least -12°C (10°F) below the lowest expected ambient temperature.
¡ Minimum cetane number is 45. Low temperature or high altitude operation may
require the use of fuel with a higher cetane number.
50% coolant mixture
SAE 10W-30
SAE 15W-40
ISO VG32
ISO VG46
ISO VG68
30% coolant mixture
SAE 90
96
Replacement
°
F
interval
°
C
Upper limit:
After first 50
7.4 (7.8)
hrs.
Lower limit:
Every 250 hrs.
4.0 (4.2)
System:120
(31.8US.gal.)
Every 2000 hrs.
Tank:79
(20.9US.gal.)
75
(19.8US.gal.)
Every 1000
7.2 (7.6)
hrs.
After first 250 hrs.*
0.8 (0.85)
Every 1000 hrs.
Every 50 hrs.
Daily or every
10 hrs.
When
required
Capacity
R(US. qt.)
As
required

Hide quick links: