After First 50 Hours; (New Machines Only) - Takeuchi TB125 Operator's Manual

Compact excavator
Table of Contents

Advertisement

MAINTENANCE
After First 50 Hours (New Machines Only)
Replacing the Hydraulic Oil
Return Filter
WARNING
¡ ¡ ¡ ¡ ¡ Stop the engine and allow the machine
to cool down before performing
maintenance.
• The engine, hydraulic lines and many
other parts of the machine are hot
directly after the engine is stopped.
Touching these parts will cause
burns.
• The hydraulic fluid is also hot and
under high pressure.
Be careful when loosening caps and
plugs. Working on the machine under
these conditions could result in
burns or injuries due to the hot oil
spurting out.
¡ ¡ ¡ ¡ ¡ Oil may spurt out if caps or filters are
removed or pipes disconnected before
releasing the pressure in the hydraulic
system.
• Gradually loosen the vent plug to
relieve tank pressure.
• When removing plugs or screws or
disconnecting hoses, stand to the
side and loosen slowly to gradually
release the internal pressure before
removing.
1
3
4
7
8
1. Slowly turn the vent plug (1) to relieve tank
pressure, then remove.
2. Loosen the bolts and remove the cover
(2).
3. Remove the return filter (3).
4. Install the new return filter.
5. Install the cover (2).
6. Inspect the level with the sight gauge (4),
and replenish if the level is low.
Refer to page 105 "Inspecting the
Hydraulic Oil Level and Replenishing".
7. Pressurize the hydraulic tank.
Refer to page 106 "Pressurizing the
Hydraulic Tank".
108
2
6
5
G4G009

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Tb145Tb135

Table of Contents