Installation Requirements
NOTE: It is most important that this salamander is installed correctly and that operation is
correct before use. Installation shall comply with local electrical, health and safety
requirements.
Blue Seal Salamanders are designed to provide years of satisfactory service, and correct installation is
essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering electrical and fire safety.
Australia / New Zealand
United Kingdom:
Installations must be carried out by authorised persons only. Failure to install equipment to
the relevant codes and manufacturer's specifications shown in this section will void the
warranty.
Unpacking
1.
Remove all packaging and transit protection from the appliance including all protective plastic
coating from the exterior stainless steel panels.
2.
Check equipment and parts for damage.
distributor.
3.
Check that the following parts have been supplied with the Salamander:
1 x Salamander Rack.
1 x Crumb Tray.
4.
Report any deficiencies to the distributor who supplied the unit.
5.
Check that the available electrical supply is correct to that shown on the rating plate located on the
front bottom corner of the right hand side panel.
Location
1.
This appliance must be mounted onto a non-combustible wall or tailored stand, using the rear wall
bracket and spacing screws provided.
2.
Combustible walls must not protrude past the front of the appliance.
3.
This appliance must not be mounted on a combustible surface or metal surface, as radiated heat will
cause these surfaces to become extremely hot.
4.
Caution should be taken as intense heat is emitted at the bottom front of the appliance.
5.
The unit should be mounted under an extraction hood in compliance with all local regulations.
In the event that the unit is not mounted under an extraction hood, the installer must ensure
that all regulations are met and that there is an unobstructed minimum distance of 750 mm
from the top surface of the unit to the ceiling, which must be of non-combustible material.
NOTE: Do not obstruct or block the appliances flue.
system to the appliance flue outlet.
Blue Seal Evolution Series Electric Salamander
Revision 1/
AS/NZS3000
- Wiring Rules.
BS 7671
- Requirements for Electrical Installations.
Report any damage immediately to the carrier and
1 x Wall Mounting Bracket, including;
- 2 x 25mm Black Plastic Spacers.
3
- 2 x
/
" Bolts / Nuts.
8
Never directly connect a ventilation
3
2

Installation

© Moffat Ltd, January 2007

Advertisement

Table of Contents
loading

Table of Contents