Summary of Contents for Blue Seal E91

  • Page 1 Manuals and Documents Brought to you by Wechillit.com Ltd WCI Group House 18 Pride Hill Shrewsbury SY1 1DQ Tel: 01743 289418 Fax: 01743 289416 Web: www.wechillit.com...
  • Page 2 Electric Salamanders S e r v i c e M a n u a l Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 3 ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY WARNING: QUALIFIED PERSONS ONLY. IMPORTANT: MAKING ALTERATIONS MAY VOID WARRANTIES AND APPROVALS. Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 4: Table Of Contents

    Contents This manual is designed to take a more in depth look at the E91 Salamander for the purpose of making the units more understandable to service people. There are settings explained in this manual that should never require to be adjusted, but for completeness and those special cases where these settings are required to change, this manual gives a full explanation as to how, and what effects will result.
  • Page 5 Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 6: Specifications

    Specifications Model Numbers Covered in this Specification Electric Salamander External Dimensions Front Side Plan Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 7: Electrical Requirements

    Width Depth Height 685 mm 330 mm 230 mm (at front) Cooking Area Rack Size 610mm x 310mm Branding Plate (accessory) 610mm x 310mm Weight (Net) 41kg Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 8: Installation

    Installation shall comply with local electrical, health and safety requirements. Blue Seal Salamanders are designed to provide years of satisfactory service, and correct installation is essential to achieve the best performance, efficiency and trouble-free operation. This appliance must be installed in accordance with National installation codes and in addition, in accordance with relevant National / Local codes covering electrical and fire safety.
  • Page 9 Lower the Salamander onto the mounting bracket. Tighten the black spacers securely and adjust the levelling screws/bolts to ensure that the unit is level.   Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 10: Electrical Connection

    F THE SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY A SUITABLY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD When connecting a Blue Seal electric appliance to the main supply, ensure that the following is carried out:- •...
  • Page 11: Operation

    The salamander has individual heat controls for Racking System the left and right sides. Select the desired heat The Rack System fitted to the Blue Seal level and allow a few minutes for the elements to Salamander is self-supporting when withdrawn, heat up.
  • Page 12: Cleaning / Maintenance

    Withdraw the left and right hand side racks from the unit. Refit the Racking in the reverse order once clean- ing has been completed. Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 13: Trouble-Shooting Guide

    One element coil does not work (Refer service section 6.2.2) Element faulty (blown). Replace. (Refer service section 6.2.1) Indicator light does not illuminate Indicator faulty. Replace. (Refer service section 6.2.3) Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 14: Service Procedures

    ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY QUALIFIED PERSONS ONLY. ENSURE GAS SUPPLY IS SWITCHED OFF BEFORE SERVICING WARNING: ALWAYS CHECK / TEST FOR GAS LEAKS AFTER SERVICE REPAIRS ON THE GAS SYSTEM Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 15: Access

    2) Remove side panel by hinging out from reverse order. bottom and lift out. NOTE: Correct element resistances (±5%): Inner Coil: 30 ohms (1900W) Outer Coil: 52 ohms (1100W) Two screws Figure 6.1.2 Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 16: Indicator Light

    4) Transfer the wires to the new selector switch, and secure to control panel with two screws. 5) Replace selector knob and control panel. NOTE: Correct switch operation: 700W 1900 3000 Selector switch Figure 6.2.2b Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 17: Accessories

    Accessories Salamander rack (017963) Wall mounting bracket (026096) Side rack (026093) Rack handle (013395) Branding plate (013418) Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 18: Exploded Parts Diagrams

    SIDE PANEL 227476 FRONT COVER 227963 NEON ORANGE 227394 KNOB BSEAL 6MM 1-2-3 005017 CONTROL PANEL ELECTRIC 026091 TRAY SUPPORT 227960 BLUE SEAL BADGE 026089 FLUE END LH Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 19 Exploded Parts Diagrams E91 Electrical and Rack Assemblies Item Part No. Description 026114 ELEMENT SUPPORT WA 013920 SALAMANDER ELEMENT SUPPORT SECURING SCREW 026088 ELEMENT 3KW DUAL COIL (Ø6.5) 017682 3 HEAT SWITCH 026160 TERMINAL BLOCK 026161 CABLE CLAMP 026093 SIDE RACK WA - SALAMANDER...
  • Page 20: Circuit Schematic

    Circuit Schematics CONTROL SWITCH SETTINGS 750W 1900W 3000W Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 21: Wiring Diagram

    Wiring Diagram Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 22: Service Contacts

    AUCKLAND - MOFFAT LTD 4 Waipuna Road Tel (09) 574 3150 Mt Wellington Fax (09) 574 3159 Auckland Spare Parts Free Call 0800 MOFFAT (0800 66 33 28) Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 23 3765 Champion Blvd Winston-Salem Tel 1800 551 8795 NC27115 Fax 336 661 9546 NATIONAL COVERAGE FOR SERVICE OR MAINTENANCE DIAL FREE CALL 1800 551 8795 (USA ONLY) Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...
  • Page 24: Appendix A. Mounting Hole Locations

    Appendix A : Mounting Hole locations Mounting hole locations Base view Rear view Dimensions shown in millimetres. All mounting holes are threaded ” BSW Blue Seal Evolution Series Electric Salamander © Moffat Ltd, January 2007 Revision 1/...