Manuals and Documents Brought to you by Wechillit.com Ltd WCI Group House 18 Pride Hill Shrewsbury SY1 1DQ Tel: 01743 289418 Fax: 01743 289416 Web: www.wechillit.com...
Contents This manual is designed to take a more in depth look at the E91 Salamander for the purpose of making the units more understandable to service people. There are settings explained in this manual that should never require to be adjusted, but for completeness and those special cases where these settings are required to change, this manual gives a full explanation as to how, and what effects will result.
Installation shall comply with local electrical, health and safety requirements. Blue Seal Salamanders are designed to provide years of satisfactory service, and correct installation is essential to achieve the best performance, efficiency and trouble-free operation. This appliance must be installed in accordance with National installation codes and in addition, in accordance with relevant National / Local codes covering electrical and fire safety.
F THE SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY A SUITABLY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD When connecting a Blue Seal electric appliance to the main supply, ensure that the following is carried out:- •...
The salamander has individual heat controls for Racking System the left and right sides. Select the desired heat The Rack System fitted to the Blue Seal level and allow a few minutes for the elements to Salamander is self-supporting when withdrawn, heat up.
Page 19
Exploded Parts Diagrams E91 Electrical and Rack Assemblies Item Part No. Description 026114 ELEMENT SUPPORT WA 013920 SALAMANDER ELEMENT SUPPORT SECURING SCREW 026088 ELEMENT 3KW DUAL COIL (Ø6.5) 017682 3 HEAT SWITCH 026160 TERMINAL BLOCK 026161 CABLE CLAMP 026093 SIDE RACK WA - SALAMANDER...