5
Trouble-shooting
ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY
WARNING:
QUALIFIED PERSONS ONLY.
Fault
The unit does not operate (neither
element works)
One element does not work
or,
One element coil does not work
Indicator light does not illuminate
Blue Seal Evolution Series Electric Salamander
Revision 1/
Possible cause
The mains isolating switch on the
wall, circuit breaker or fuses are
"off" at the power board.
Incorrect electrical supply.
Selector switch on unit faulty.
Element faulty (blown).
Indicator faulty.
8
Remedy
Turn on.
Ensure electrical supply correct.
Check switch poles - replace if
faulty.
(Refer service section 6.2.2)
Replace.
(Refer service section 6.2.1)
Replace.
(Refer service section 6.2.3)
© Moffat Ltd, January 2007